Operating the Charbroiler - Pilot Lighting Instructions 

 

Before operating charbroiler, it should be checked to see that it is sitting level. Adjust the feet to 
level the charbroiler. Be sure the catch tray has been properly placed.   
The pilot light on the appliance have been set at the factory. Each burner has a pilot light.   

1.

 

Make sure all knobs are in the “OFF” position. 

 

2.

 

The main gas valve should be “CLOSED/OFF” for five (5) minutes prior to lighting        pilots to clear 

any existing gas. (Main gas valve is supplied by others.)   

3.

 

Turn “ON/OPEN” the main gas valve to the unit.   

4.

 

Light and hold an ignition source (match) at the pilots. When the flame is established,    remove       
the ignition source. Repeat this step for each burner as each burner has its own individual pilot.   

The pilot can be reached through the holes on the front of the unit or through the top grate. 
Remove the radiant before attempting to light.   

5,          Adjust the pilot valve, make sure the pilot flame at 1/2 inch height. 

Turn each burner knob 

“ON”. If the burners do not ignite promptly, turn the knobs “OFF”. From the 

opening in the front panel, use a screwdriver and turn the pilot valve screw counterclockwise 
which will increase the flame height and repeat step 4.   

If the pilot flame appears larger than necessary, turn it down and reset burner ignition. The pilot 

flame should be as small as possible but large enough to guarantee reliable ignition of the 
burners when the knobs are turned to “ON”. The holes located in the front panel are pilot valve 
adjustments. Use a screwdriver to turn the valve to adjust the flame height to your desired level.   

 

Igniting the Burner 

 

To ignite the burner, turn knob to the “ON” position. Then back off to the desired flame level. The 
range of adjustment is virtually infinite between “ON” and “OFF”.   
The space between the legs at the bottom admits combustion air. DO NOT BLOCK THIS SPACE.   
All burners are lit from a constantly burning pilots. Turning the valve to the desired flame height is all that is   
required to put the unit in service.   
Do not permit fans to blow directly at the unit. Wherever possible, avoid open windows next to the un

it’s 

sides or back. Avoid wall type fans which create air cross-currents within a room.   

It is also necessary that sufficient air should be allowed to enter the room to compensate for 
the amount of air removed by any ventilating system. Otherwise, a subnormal atmospheric 
pressure will occur, affecting operation and causing undesirable working conditions.   

A properly designed and installed hood will act as the heart of the ventilating system for the room or area in 
which the unit is installed, and will leave the unit independent of changing draft conditions.   

NOTE: It may be necessary to adjust the balance of gas, volume and air supply to each   
burner. This must be done by an authorized service technician. 
 

Shutdown burner 

To turn 'OFF' the appliance completely, turn the gas control knob completely clockwise to the 'O' position, the 
pilot burner will extinguish. 
 
 
 
 
 
 
 

 
 

 
 
 
 
 

Summary of Contents for KF-CB12-M

Page 1: ...r Service on Your Gas Charbroiler Please call the KFE Service Department and ask for contact information for your local service company WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT ...

Page 2: ...2 This manual contains important safety instructions which must be strictly followed when using this equipment Please retain this manual for future reference ...

Page 3: ...3 Index ATTENTION OWNERS AND OPERATORS 3 UNPACKING INSTALLATION 4 5 WARNINGS SAFEGUARDS FOR OPERATION 6 OPERATING INSTRUCTIONS 7 8 CLEANING INSTRUCTIONS 9 10 TROUBLESHOOTING 11 LIMITED WARRANTY 12 ...

Page 4: ...pany cannot anticipate every circumstance or environment in which its equipment will be operated It is the responsibility of the owner and the operator to remain alert to any hazards posed by the function of this equipment If you are ever uncertain about a particular task or the proper method of operating this equipment ask your supervisor This manual contains a number of precautions to follow to ...

Page 5: ...tem at test pressures in excess of psi 3 45 kPa These models are designed built and sold for commercial use only Instructions must be posted in a prominent location All safety precautions must be taken in the event the user smells gas Safety information can be obtained from your local gas supplier UNPACKING Unpack the charbroiler immediately after receipt Remove the gas charbroiler from the crate ...

Page 6: ...with legs mounted lift if necessary to move unit 7 The supplied gas pressure regulator is factory set at 4 Natural gas W C or 10 for L P 8 THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON COMBUSTIBLE SURFACES ONLY Noncombustible clearances 0 sides 0 mm 6 rear 152 mm 4 floor 102 mm 9 Do not obstruct the flow of combustion and ventilation air under the unit by the legs or behind the unit by the flue...

Page 7: ...lways turn off the unit when not in use servicing or adjusting any parts or attachments and before cleaning Never leave the charbroiler on overnight Do not operate any equipment with a damaged or leaking gas line ignitor or valves or if the unit is dropped or damaged in any manner Call for service The use of attachments not recommended or sold by the manufacturer may cause fire injury or even deat...

Page 8: ...rantee reliable ignition of the burners when the knobs are turned to ON The holes located in the front panel are pilot valve adjustments Use a screwdriver to turn the valve to adjust the flame height to your desired level Igniting the Burner To ignite the burner turn knob to the ON position Then back off to the desired flame level The range of adjustment is virtually infinite between ON and OFF Th...

Page 9: ...approach to the loading of the unit will produce the most consistent product results NOTE When the charbroiler is first heated it will smoke until oil used in manufacturing preservation and dust from storage and shipping are burned off An hour at max on all burners is usually sufficient Radiant Charbroiler 1 Place the angled radiants in their position as shown in 8 1 2 Make sure that the radiants ...

Page 10: ... follow the cleaning steps below PART REQUIRED ACTION FREQUENCY Body Use a clean cloth and a non abrasive cleaner to clean the stainless steel body of the charbroiler Wipe the polished areas with a soft cloth Daily Controls Unit should be turned off when not in use It is recommended that the unit be disconnected from the gas supply by closing the main gas valve Use a clean cloth to wipe any down c...

Page 11: ...tted to fill too high grease debris is likely to accumulate under the unit The catch tray drawer is removed by pulling forward USE CAUTION WHEN REMOVING per Use or at least Daily Burner Air Shutter Openings Main burner ports must be kept clean Close the gas valve to the unit shutting off the gas and extinguishing the pilot light Clean in place with a wire brush or clean gas ports with a sharp poin...

Page 12: ...as line leak Turn off main gas valve DO NOT LIGHT FLAME ignite anything or turn switch on anything electrical Call fire department if needed and call for service Cooking surface is heating up slowly Carbon build up Ensure that the burners are kept clean and free from carbon build up debris Gas type of unit needs to be converted Unit ships from the factory Natural gas Conversion from Natural Gas to...

Page 13: ...nversion from Natural Gas to Propane L P on all models The conversion should be done before connecting the unit to the gas supply Units are shipped from the factory equipped for use on natural gas Parts necessary for L P liquid propane are provided with the unit Turn off the main gas supply before doing any maintenance 1 Remove the knobs and front panel 2 Unscrew bolts and pilot valve then remove ...

Page 14: ...14 6 Continue with installation L P Position of insert Regulator is now converted to L P ...

Page 15: ...ecognize however that replacement parts and occasional professional service may be necessary to extend the useful life of this unit When service is needed contact a KFE Authorized Service Agency or your dealer To avoid confusion always refer to the model number serial number and type of your unit ...

Page 16: ...16 NOTES ...

Reviews: