5
Gas Supply and Burner Information
Supply pressure should be minimum of 4" W.C. for natural gas or 10" W.C. for propane. The fryer comes
with ¾” NPT male connector on a ½” pipe, allowing you to connect with either ¾” or ½” NPT female
connector.
Model
Burners
Gas Type
Manifold
Pressure
Number of
heat tube
Rate Each
BTUs / Hour
Total Rate
BTUs / Hour
Orifice Size
3 burners
fryer NG
3 burners
fryer LP
Main
Natural
4" W.C.
3
30,000
90,000
# 39
Propane
10" W.C.
3
30,000
90,000
# 52
4burners
fryer NG
4 burners
fryer -LP
Main
Natural
4" W.C.
4
30,000
120,000
# 39
Propane
10" W.C.
4
30,000
120,000
# 52
5 burners
fryer -NG
5 burners
fryer -LP
Main
Natural
4" W.C.
5
30,000
150,000
# 39
Propane
10" W.C.
5
30,000
150,000
# 52
* Minimum supply pressure is 4" W.C. for natural gas and 10" W.C. for propane.
** Orifice sizes are for units installed at altitudes between 0 and 2000 feet above sea level.
I
NSTALLATION
NOTICE
Installation must conform with local codes, or in the absence of local codes, with the
National Fuel Gas
Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1,
or the
Propane Installation Code,
CAN/CGA-B149.2,
as applicable.
NOTICE
These installation procedures must be followed by qualified personnel or warranty will be void.
Local codes regarding installation vary greatly from one area to another. The National Fire Protection
Association, Inc. states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction”
when it comes to installation requirements for equipment.
Summary of Contents for KF-F3-LP