6
RTB SERIES CABLE REEL MANUAL
KH200-02619_REV-A
SECTION 2 - SAFETY
Electrical Rating
Reels equipped with or without cable.
Cord reels equipped with cable are rated and should not be used at voltages and/or amperes above the rating on
the reel. Please consult factory prior to making any changes in volts and amps of cable, as a change could affect
reliability or safety.
Color Code Chart
Location of
Ring
No. of
Conductor
Base
Color
top
Ground
Green
2nd from top
2
Black
3rd from top
3
White
bottom
4
Red
Cable
AWG / # of
Cond.
Ampacity
16/3
10
16/4
8
14/3
15
14/4
12
12/3
20
12/4
16
Labels & Marking
Every cord reel is marked with a label which includes the KH Industries name
and logo, the product catalog number, the individual product serial number,
NEMA rating, Amps, Volts, Watts and Cable Footage.
The UL / CSA Listing mark is applied to reels that comply with the applicable
requirements and identified with the authorized mark.
The maximum cable footage, amperage and voltage rating for every cable
reel supplied without cable is marked on the KH Industries Identification
Label. The actual cable installed should not differ from what is indicated
on the KH Industries label. If the cable must be different please consult the
factory prior to installing the cable to ensure the change will not affect the
reliability of the reel or the safety of the people working with the cord reel.