15
Kice InDustries, Inc.
FLT-M03-0002
012420
Installing / Replacing Bags and Cages - Accessing Dirty Air Chamber
1. Locate proper cleaning platform (see Figure 5.1 and 5.2).
2. Remove any fi lter bags that may interfere with the position of the cleaning platform inside the
chamber.
3. Place cleaning platform inside the fi lter access door as shown (see Figure 6.1 and 6.2). For door
mount platform, make sure the tabs on both sides of the cleaning platform are on the outside of the
door frame. Check to make sure the cleaning platform is level and secure. The platform should not
rest against or interfere with any fi lter bags inside the chamber.
NOTICE:
A hook is located on the bottom of the tube sheet that may be used to provide additional
balance and stability when accessing the dirty air chamber (see Figure 4).
Installation Continued
Figure 4
WARNING:
The hook on the bottom of the tube sheet is not intended to be a tie off point for
a fall arrest system.
Stability Hook