11. Appendix B

™  

  

ASCO Valves

® 

           

 

E265662 - 06/2016

           All Rights Reserved. 

         I&M No. V_6584_R19_sec1

 ©

ASCO Valve, Inc.

 

50 Hanover Road, Florham Park, New Jersey 07932              www.ascovalve.com                    

Page 1 of 6

I&M No. V_6584_R19_sec1

Installation&Maintenance Instructions 

 

OPEN-FRAME, GENERAL PURPOSE, WATERTIGHT/EXPLOSIONPROOF SOLENOIDS 

OPTIONAL FEATURE FOR OPEN FRAME (GENERAL PURPOSE) CONSTRUCTION ONLY

SERIES 

8003G/H 

8007G/H

8202G/H 

— SERVICE NOTICE — 

ASCO

®

  solenoid valves with design change letter “G” or “H” 

in the catalog number (ex. 8210G1) have an epoxy encapsulated 

ASCO

 Red Hat II

 solenoid. This solenoid replaces some of 

the solenoids with metal enclosures and open

-

frame constructions. 

Follow these installation and maintenance instructions if your 

valve or operator uses this solenoid. 

See separate instructions for basic valve.  

DESCRIPTION 

Catalog numbers 8003G/H, 8007G/H and 8202G/H and are 

epoxy encapsulated pull-type solenoids. The green solenoid 

with lead wires and 1/2 conduit connection is designed to 

meet Enclosure Type 1-General Purpose, Type 2-Dripproof, 

Types 3 and 3S-Raintight, and Types 4 and 4X-Watertight. The 

black  solenoid  on  catalog  numbers  prefixed  “EF”  or  “EV”  is 

designed to meet Enclosure Types 3 and 3S-Raintight, Types 

4 and 4X-Watertight, Types 6 and 6P-Submersible, Type 7, 

Explosionproof Class I, Division1 Groups A, B, C, & D and 

Type 9, -Dust-Ignitionproof Class II, Division1 Groups E, F & 

G. The Class II, Groups F & G Dust Locations designation is 

not applicable for solenoids or solenoid valves used for steam 

service or when a class “H” solenoid is used. See

 Temperature 

Limitations

  section  for  solenoid  identification  and  nameplate/

retainer for service. When installed just as a solenoid and not 

attached to an ASCO valve, the core has a 0.250-28 UNF-2B 

tapped hole, 0.38 or 0.63 minimum full thread. 

NOTE:

  Catalog  number  prefix  “EV”  denotes  stainless  steel 

construction. 

Solenoid catalog numbers 8202G/H1, 8202G/H3, 8202G/H5 

and 8202G/H7 are epoxy encapsulated push-type, reverse-acting 

solenoids having the same enclosure types as previously stated 

for Catalog numbers 8003G/H1 and 8003G/H2.  8007G/H are 

3-way solenoid operators with a pipe port or adapter, exhaust 

protector or vent at the top of the solenoid base sub-assembly. 

Series 8003G/H, 8007G/H and 8202G/H solenoids are  also 

available in: 

• 

Open-Frame Construction:

  The green solenoid may be 

supplied with 1/4˝ spade, screw or DIN terminals. (Refer to 

Figure 4) 

□  DIN Plug Connector Kit No. K236034:  

Use this kit 

only for solenoids with DIN terminals. The DIN plug 

connector kit provides a two pole with grounding contact 

DIN Type 43650 construction (See Figure 6). 

• 

Panel Mounted Construction:

 These solenoids are 

specifically designed to be panel mounted by the customer. 

Refer  to  Figures  specified  in  this  I&M  and  the  section  on 

Installation of Panel Mounted Solenoid

 for details. 

• 

Junction Box:  

This junction box construction meets 

Enclosure Types 2, 3, 3S, 4, and 4X. Only solenoids with 

1/4˝ spade or screw terminals may have a junction box. The 

junction box provides a 1/2˝ conduit connection, grounding 

and spade or screw terminal connections within the junction 

box (See Figure 5).  

• 

Multipin Connectors:  

All Multipin connectors (VT, VB, 

ZT, ZB) do not have any enclosure ratings.

NOTE:  

For China RoHS Hazardous Substances 

table, please go to the link below or scan QR code:

www.asco.com/ChinaRoHSDisclosure

OPERATION

 

Series 8003G/H and 8007G/H - When the solenoid is energized, 

the core is drawn into the solenoid base sub-assembly. 

IMPORTANT:  When  the  solenoid  is  de-energized,  the 

initial  return  force  for  the  core,  whether  developed  by 

spring,pressure,  or  weight,  must  exert  a  minimum  force 

to  overcome  residual  magnetism  created  by  the  solenoid. 

Minimum return force for AC construction is 11 ounces, and 

5 ounces for DC construction. 

Series 8202G/H - When the solenoid is energized, the disc 

holder assembly seats against the orifice. When the solenoid is 

de-energized , the disc holder assembly returns.

 IMPORTANT: 

Initial  return  force  for  the  disc  or  disc  holder  assembly, 

whether developed by spring, pressure, or weight, must exert 

a minimum force to overcome residual magnetism created 

by the solenoid. Minimum return force is 1pound, 5 ounces. 

INSTALLATION 

Check nameplate for correct catalog number, service, and 

wattage. Check front of solenoid for voltage and frequency. 

      WARNING: 

Electrical hazard from 

the accessibility of live parts. To prevent the 

possibility of death, serious injury or property 

damage, install the open - frame solenoid in 

an enclosure. 

AVERTISSEMENT: Risque d’accès aux 

parties  électriques  actives.  Afin  d’éviter 

tout risque de mort, blessure ou dommage, 

installer la bobine dans un boitier.

FOR BLACK ENCLOSURE TYPES 7 AND 9 ONLY 

      

 CAUTION: To prevent fire or explosion, do not install 

solenoid and/or valve where ignition temperature of 

hazardous atmosphere is less than 165°C. On valves 

used for steam service or when a class “H” solenoid 

is used, do not install in hazardous atmosphere 

where ignition temperature is less than 180°C. See 

nameplate/retainer for service. 

ATTENTION  :  Afin  d’éviter  le  risque  de  de 

feu ou d’explosion, ne pas installer la bobine ou 

l’électrovanne  ou  la  température  d’inflammation  en 

atmosphère explosible est inferieure à 165°C. Pour 

les vannes vapeur ou lorsqu’une bobine de classe H 

est utilisée, ne pas installer en atmosphère explosible 

lorsque  la  température  d’inflammation  est  inférieure 

à 180°C. Consulter les conditions d’utilisations sures 

indiquées sur le produit ou dans la notice.

NOTE:

 These solenoids have an internal non-resetable thermal 

fuse to  limit solenoid temperature in the event that extraordinary 

conditions occur which could cause excessive temperatures. 

These conditions include high input voltage, a jammed core, 

excessive ambient temperature or a shorted solenoid, etc. This 

unique feature is a standard feature only in solenoids with black 

explosionproof/dust-ignitionproof enclosures (Types 7 & 9). 

Summary of Contents for Pneu-Jet Filter

Page 1: ...1 Kice InDustries Inc FLT M03 0002 012420 Operators Manual Pneu Jet Filter Skilled Air for Industry Operators Manual Pneu Jet Filter Pneu Jet Filter Skilled Air for Industry...

Page 2: ...from the date of shipment Company agrees to repair or replace at its option any parts found to be defective in the opinion of the Company Company is not liable for any costs in connection with the re...

Page 3: ...tion 4 3 General Information 5 4 Safety Precautions 9 5 Delivery Inspection and Installation Preparation 12 6 Storage 13 7 Installation 13 8 Filter Operation and Start Up Procedure 19 9 Filter Mainten...

Page 4: ...or additional information application assistance or special service please contact us by phone at 316 744 7151 or email at sales kice com We ll need to know the MODEL and SERIAL NUMBER of your Kice Pn...

Page 5: ...erms disconnect and lockout or lockout tagout as used in this manual means that power to the Kice Pneu Jet filter has been disconnected through the use of a padlockable manual power cutoff or power lo...

Page 6: ...ts contact the Customer Service Department or Quick Ship Department Kice Industries Inc 5500 Mill Heights Drive Wichita Kansas 67219 2358 Toll Free 877 289 5423 Main Phone 316 744 7151 Fax 316 744 735...

Page 7: ...chased items such as speed reducers motors and positive pressure pumps are covered by the manufacturer s warranty If there is a problem with a purchased item check with the local supplier or service r...

Page 8: ...res The following publications provide valuable information on fire and explosion protection and can be helpful to insure your facility is properly equipped NFPA 652 Standard on the Fundamentals of Co...

Page 9: ...r personal safety When you see this symbol be alert Your personal safety or the safety of others may be affected Follow the instructions in the safety message Safety Decals The Kice Pneu Jet filter de...

Page 10: ...s all moving parts are completely enclosed and all guards grates and maintenance panels are in place and securely fastened All protective covers guards grates maintenance panels switches and warning d...

Page 11: ...omplete required Kice Pneu Jet filter service Never stand under any kind of hoists or lifting mechanisms whether or not it is loaded or in operation Never stand under or near a Kice Pneu Jet filter or...

Page 12: ...filter is still secured to freight platform Slab Mounted Units A qualified engineer should design the foundation and or footings for the filter The slab should be extended to support accessory equipme...

Page 13: ...ound each hole and mount the filter housing 4 If an airlock valve is required it should be mounted to the hopper discharge flange or sight glass assembly Additional support may be required 5 Tighten a...

Page 14: ...ch air tank has its own junction box A local electrician must run a conduit from the control box to each junction box on the filter Wiring from the controller to the junction box terminals should be 1...

Page 15: ...form make sure the tabs on both sides of the cleaning platform are on the outside of the door frame Check to make sure the cleaning platform is level and secure The platform should not rest against or...

Page 16: ...stem NOTICE Kice Industries Inc will always supply internal safety grating in the bottom of the filter housing if it is to be mounted onto a storage bin to prevent personnel bags and cages from droppi...

Page 17: ...igure 7 Installation Continued Figure 7 2 Check the filter bag for proper length The filter bag should be only 2 longer than the bag retainer cage 3 Tuck the overextended portion of the filter media i...

Page 18: ...the assembly from slipping off see Figure 11 7 Tighten the clamp with either a screwdriver a nut runner with a 5 16 socket or a ratchet with an extension which will help facilitate the installation It...

Page 19: ...pressurized air through the manifold into the top of each bag in that row This pulse of air causes the dust particles collected externally on the filter media to be dislodged and fall into the hopper...

Page 20: ...es the pressure equalizes allowing the diaphragm to close As the pulse of air is fired through the manifold and down the tubes located above the filter bag the pulse creates a shock effect that dislod...

Page 21: ...ller will activate the outputs sequentially whenever the pressure switch contacts are closed When the pressure switch contacts open the output sequencing stops Reclosing of the contacts will cause the...

Page 22: ...ration Start Up Procedure Continued The DCT510ADC operates on 10 to 35 VDC The DCT500ADC Low Cost Timer Controller is designed for continuous cleaning methods or on demand pulse jet cleaning systems D...

Page 23: ...Milliseconds Opera ng Voltage 120 10 VAC 50 60 Hz O Time Adjustable from 1 to 180 Seconds DCT1022DC Adjustable from 1 to 225 Seconds Op onal Voltage 220 10 VAC 50 60 Hz Output Protection Type 10 30 V...

Page 24: ...vate followed by an independently timed off period Each time sequence is infinitely adjustable within the stated time range Following the number 1 on and off time the number 2 on and off time will be...

Page 25: ...x 10 x 5 11 20 DNC T2032 A10 32 14 x 12 x 6 17 32 1994 to 2008 Specifications Time Delay Input On Time Adjustable from 50 to 500 Milliseconds Opera ng Voltage 120 10 VAC 50 60 Hz O Time Adjustable fr...

Page 26: ...shipment and to allow a short run in time for the electronics 6 Set the controller off time adjustment to a longer time span by rotating the dial clockwise until you cannot turn the dial any further W...

Page 27: ...ssure to valve must be within 2 15 psig 2 Excessive leakage Disassemble valves and clean all parts Replace parts that are worn or damaged with a complete Spare Parts Kit see Figure 16 3 Failure to Ope...

Page 28: ...ure the air tank is at atmospheric pressure 1 The solenoid operated pilot valve is mounted to the main valve bonnet with four screws Remove bonnet screws valve bonnet diaphragm spring and diaphragm as...

Page 29: ...29 Kice Industries Inc FLT M03 0002 012420 Filter Maintenance and Service Continued Figure 16...

Page 30: ...en solenoid with lead wires and conduit connection is designed to meet Enclosure Types 4 and 4X Watertight The black solenoid designated by catalog number prefix EF is designed to meet Enclosure Types...

Page 31: ...e dust may buildup to the point that the filter media needs to be removed for cleaning This condition may be corrected by running the cleaning cycle without the dusty air flowing through the filter me...

Page 32: ...or leaks a Check the Pneu Jet blast valves for leaks b Check to see if any of the Pneu Jet blast valves are stuck open and bleeding the tank air straight to the filter The electric operated 2 way pilo...

Page 33: ...rce 4 DO NOT mount the control in a high transient voltage area without an isolation transformer 5 DO NOT leave the control box door open 6 DO NOT allow a local repair shop to repair the controller Fo...

Page 34: ...ld Kit number stamped on the valve nameplate When Ordering Coils for ASCO valves order the number stamped on your coil If the number of the kit or the coil is not visible order by indicating the numbe...

Page 35: ...tion Box This junction box construction meets Enclosure Types 2 3 3S 4 and 4X Only solenoids with 1 4 spade or screw terminals may have a junction box The junction box provides a 1 2 conduit connectio...

Page 36: ...uctions For Optional Features Open Frame solenoid with 1 4 spade terminals For solenoids supplied with screw terminal connections use 12 18 AWG stranded copper wire rated at 90 C or greater Torque ter...

Page 37: ...nal valve parts for damage or excessive wear is recommended Thoroughly clean all parts Replace any worn or damaged parts Causes of Improper Operation Faulty Control Circuit Check the electrical system...

Page 38: ...g Series 8202G without adapter Torque Chart Part Name Torque Value in Inch Pounds Torque Value in Newton Meters solenoid base sub assembly 175 25 19 8 2 8 pipe adapter 90 maximum 10 2 maximum adapter...

Page 39: ...inal block see note junction box gasket junction box with 1 2Iconduit connection and grounding terminal cover screw cover cover gasket grounding screw and cup washer gasket DIN terminal adapter See to...

Page 40: ...nut gland gasket washer center screw Figure 6 DIN plug connector kit No K236034 optional feature See torque chart above Page 6 of 6 I M No V_6584_R19_sec2 ASCO Valve Inc 50 Hanover Road Florham Park...

Page 41: ...8 Socket head Socket head cap screw cap screw Bolt Thread Dia Size 1 4 20 8 4 11 12 16 11 15 5 16 18 17 24 25 33 23 31 3 8 16 31 42 44 59 41 55 7 16 14 49 67 70 95 65 59 1 2 13 74 100 110 140 100 140...