If required, It is possible to hard wire the DC charging Output Leads to the battery
for permanent installations.
You will need an Adaptor Lead with Ring Terminals, Fuse, Fuse Holder and a
suitable Plug to attach to the current Charger Plug.
Alternatively, if you would like to install this yourself please follow the steps below:
1. Cut off the supplied battery clips; ensure you leave sufficient cable to reach the
battery terminals. (DO NOT extend the battery charger DC output cables, as the
added voltage drop will cause incorrect charging).
2. Fit a ring terminal to the BLACK Negative (-) wire.
3. Connect the In-line fuse to the RED Positive (+) wire.
4. Connect a ring terminal to the other end of the in-line fuse.
5. Connect the RED Output Lead (with in-line fuse and ring terminal) to the Positive
(+) battery post.
6. Connect the BLACK lead (with ring terminal) to the Negative (-) Battery Terminal.
7. Fit the correctly rated fuse. (Recommended: Double the chargers current rating)
If the charger is used in a Permanent / Hard Wired application and the vehicle
will not be used for extended periods of time, it is best to leave the charger
connected to mains power (turned 'On') so that it can maintain and keep the
the battery fully charged.
Ensure any modification to the 220-240V AC mains lead is carried out
by a qualified person and that connection to mains supply is in accordance
with the National wiring rules.
Inline fuse
RED
BLACK
Ring terminal
OUTBACK PROOF GEAR
GEL
AGM
WET
CAL
HOLD
PRESS
12 VOLT
BATTERY TYPE
POWER ON/OFF
SMART/AUTOMATIC
CHARGED
6
5
4
3
2
1
maintain
recond
analyse
absorption
bulk
soft start
desulphation
7
8
BATTERY
CHARGER
PERMANENT WIRING TO BATTERY
16