background image

Carbon Monoxide Alarm Procedure

If alarm sounds 4 quick beeps, 5 seconds off:

1)

Immediately move to fresh air - outdoors or by an open

door/window. Do a head count to check that all persons are
accounted for. Do not re-enter the premises nor move away
from the open door/window until the emergency services
responders have arrived, the premises have been aired out, and
your alarm remains in its normal condition.

2)

Call your emergency services (Fire Department or 911);

Never restart the source of a CO problem until it has been
corrected. Never ignore the sound of the alarm!

If the alarm is sounding, pressing the Test/Hush button will
terminate the alarm. If the CO condition that caused the alert
in the first place continues, the alarm will reactivate. If the
unit alarms again within six minutes, it is sensing high levels
of CO which can quickly become a dangerous situation.

WARNING:

Activation of the CO 

Alarm indicates the presence of Carbon
Monoxide (CO) which can kill you.

PHONE NUMBER:

What to do When the Alarm Sounds!

2548-7201-01_EN.qxp__  15-6-1  下午1:38  页 2

Summary of Contents for 900-0284

Page 1: ...user guide which should be saved for future reference and passed on to any subsequent owner Carbon Monoxide Alarm User Guide Model KN COP DP 10YH 900 0284 AC Plug in Operated with Sealed Lithium Batt...

Page 2: ...ency services Fire Department or 911 Never restart the source of a CO problem until it has been corrected Never ignore the sound of the alarm If the alarm is sounding pressing the Test Hush button wil...

Page 3: ...ur smoke alarm is alarming in a non emergency situation Because your sense of sight smell hearing and touch give you information you can almost instantly judge what action to take if you hear your smo...

Page 4: ...ndividuals from acute effects of carbon monoxide exposure It may not fully safeguard individuals with specific medical conditions If in doubt consult a medical practitioner Individuals with medical pr...

Page 5: ...dicate that while victims are aware they are not well they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance Also young children and hou...

Page 6: ...50 PPM Kidde recommends you take action to eliminate the source of CO See What to do When the Alarm Sounds inside front cover Possible Sources of Carbon Monoxide Inside your home appliances used for...

Page 7: ...nd if you suspect CO poisoning move outside to fresh air and get emergency help Your first line of defense is an annual inspection and regular maintenance of your appliances Contact a licensed contrac...

Page 8: ...ed by Doors or other obstructions Fresh air from a vent an open window or other source CO being present on one level of the home and not reach a CO alarm installed on a different level For example CO...

Page 9: ...arm is monitoring for CO If the alarm does not go into Low Battery Hush the battery power is below the Low Battery Hush threshold REPLACE THE ALARM IMMEDIATELY Ambient Light Sensor This alarm includes...

Page 10: ...LY Night Light Escape Light Feature This model is equipped with a night light feature The brightness of the night light can be adjusted by the user pushing the peak level button and holding the button...

Page 11: ...not install in areas where the temperature is colder than 4 4 C 40 F or hotter than 37 8 C 100 F such as crawl spaces attics porches and garages Do not install within 1 5 m 5 of heating or cooking app...

Page 12: ...s the battery backup when the alarm is plugged into an AC outlet for the first time CAUTION Do not rotate the alarm while it is plugged into an outlet as damage to plug may result Important Labels Pro...

Page 13: ...ng for CO Verify AC power is restored as soon as possible to conserve battery 6 Operating Characteristics This alarm will display a 0 if CO concentrations between 0 and 30 PPM have been detected withi...

Page 14: ...PPM Although the Peak Level feature will display levels below 30 PPM these levels will not result in an alarm no matter how long the device is exposed to these levels The Peak Level feature is helpfu...

Page 15: ...remove accumulated dust Never use detergents or solvents to clean the alarm Chemicals can permanently damage or temporarily contaminate the sensor Avoid spraying air fresheners hair spray paint or ot...

Page 16: ...io communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which c...

Page 17: ...warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of consequential or incidental damages so the above limitations or exclusions may not...