background image

Smoke alarms should not be installed within 0.9m (3ft) of the following: the door to
a kitchen, the door to a bathroom containing a tub or shower, ceiling or whole
house ventilating fans or other high air flow areas..

Kitchens: Normal cooking may cause nuisance alarms. If a kitchen alarm is desired, it
should have an alarm silence feature or be a photoelectric type.

Smoke alarms are not to be used with detector guards unless the combination

(alarm and guard) has been evaluated and found suitable for that purpose.

WARNING:

To reduce the risk of fire or electric shock, do not expose this apparatus

to rain or moisture.

3.INSTALLATION INSTRUCTION

CAUTION: THIS UNIT IS SEALED. THE COVER IS NOT REMOVABLE!

1). Remove the mounting plate from the back of the alarm by holding the mounting

plate and twist the alarm in the direction indicated by the “REMOVE” arrow see
Figure 4.

2). To ensure aesthetic alignment of the alarm with the hallway, the “A” line on the

mounting plate should be parallel with the hallway when ceiling mounting.

3). After selecting the proper smoke alarm location as described in Section 1, attach the

mounting plate to the ceiling as shown in Figure 1. Use the screws and anchors
provided to secure the mounting plate.For wall mounting, see FIGURE 2. Be sure to
turn the text "UP" and the arrow up.

4). When installing the battery, press the battery reminder finger down into the battery

compartment and install the battery (see Figure 3).

C

CA

AU

UT

TIIO

ON

N!!  IIF

F  T

TH

HE

E  B

BA

AT

TT

TE

ER

RY

Y  R

RE

EM

MIIN

ND

DE

ER

R  F

FIIN

NG

GE

ER

R  IIS

S  N

NO

OT

T  H

HE

EL

LD

D  D

DO

OW

WN

N  IIN

N  T

TH

HE

E

B

BA

AT

TT

TE

ER

RY

Y  C

CO

OM

MP

PA

AR

RT

TM

ME

EN

NT

T  B

BY

Y  T

TH

HE

E  B

BA

AT

TT

TE

ER

RY

Y,,  T

TH

HE

E  U

UN

NIIT

T  W

WIIL

LL

L  N

NO

OT

T  A

AT

TT

TA

AC

CH

H  T

TO

O

T

TH

HE

E  M

MO

OU

UN

NT

TIIN

NG

G  B

BR

RA

AC

CK

KE

ET

T..

5). Alignment marks are provided on the edge of the trim plate and the alarm. After

installing the mounting plate, place the alarm on the mounting plate with the
alignment marks lined up. Twist the alarm in the direction indicated by the “ON”
arrow on the alarm cover (see Figure 4) until it locks in place.

6). Tamper Resist Feature: To make your smoke alarm tamper resistant, a tamper resist

feature has been provided. Activate the tamper resist feature by breaking out the
block in the trim ring (see Figure 5). When the blocks are broken out, the tamper
resist tab is allowed to engage the mounting bracket. Rotate the alarm onto the
mounting bracket until you hear the tamper resist tab snap into place, locking the
alarm on the mounting bracket. Using the tamper resist feature will help to deter
children and others from removing the alarm from bracket. NOTE: To remove the
alarm when the tamper resist tab is engaged, press down on the tamper resist tab
with a screwdriver, and rotate the alarm off of the bracket (see Figure 6).

CAUTION! EARLY WARNING FIRE DETECTION IS BEST ACHIEVED BY THE

INSTALLATION OF FIRE DETECTION EQUIPMENT IN ALL ROOMS AND AREAS OF
THE HOUSEHOLD AS FOLLOWS:

A SMOKE ALARM INSTALLED IN EACH SEPARATE SLEEPING AREA (see DIAGRAM
"B" and "RECOMMENDED LOCATIONS FOR ALARMS") AND HEAT OR SMOKE
ALARMS IN THE LIVING ROOM, DINING ROOM, KITCHEN, HALLWAYS, ATTIC,
BOILER ROOM, CLOSETS, UTILITY STORAGE ROOM, CELLAR, AND ATTACHED
GARAGE.

!!

!!

!!

!!

0306-7276-02_DY29_UK:_  2021.6.10  2:01 PM  Page 5

Summary of Contents for DY29

Page 1: ...nothing less when the lives of your family are at stake Please take a few minutes to read this User Guide and save it for future reference Teach children how to respond to the alarms and that they sho...

Page 2: ...TRUCTIONS BEFORE INSTALLATION AND KEEP THIS USER GUIDE NEAR THE ALARM FOR FUTURE REFERENCE IMPORTANT ADDITIONAL MARKINGS CAN BE FOUND ON BACK OF THE ALARM CONTENTS OF THIS USER GUIDE 1 RECOMMENDED LOC...

Page 3: ...all be located on the high side of the room A row of detectors shall be spaced and located within 0 9m 3ft of the peak of the ceiling measured horizontally see DIAGRAM C Put smoke alarms at both ends...

Page 4: ...n cause nuisance alarms In areas where the Relative Humidity RH is above 93 Do not install where the ventilation openings in the unit could be impeded by items such as newspapers table cloths curtains...

Page 5: ...O OT T H HE EL LD D D DO OW WN N I IN N T TH HE E B BA AT TT TE ER RY Y C CO OM MP PA AR RT TM ME EN NT T B BY Y T TH HE E B BA AT TT TE ER RY Y T TH HE E U UN NI IT T W WI IL LL L N NO OT T A AT TT T...

Page 6: ...nger into battery box see Step No 4 FIGURE 4 FIGURE 5 Break Push FIGURE 6 FIGURE 2 e door to hole desired it tion pparatus unting w see n the ttach the chors sure to battery N THE H TO After he ON er...

Page 7: ...RATION Erratic or low sound coming from your alarm may indicate a defective alarm that should be returned for service NOTE If at any time your alarm fails to operate correctly erratic or low sound for...

Page 8: ...MEDIATELY NOTE DENSE SMOKE WILL OVERRIDE THE HUSH CONTROL FEATURE AND SOUND A CONTINUOUS ALARM CAUTION BEFORE USING THE ALARM SMART HUSHFEATURE IDENTIFY THE SOURCE OF THE SMOKE AND BE CERTAIN A SAFE C...

Page 9: ...larms be installed to help insure maximum detection of the various types of fires that can occur within the home Ionisation sensing alarms may detect invisible fire particles associated with fast flam...

Page 10: ...xtinguishers on every level of the home and in the kitchen basement and garage Know how to use a fire extinguisher prior to an emergency Current studies have shown smoke alarms may not awaken all slee...

Page 11: ...proper maintenance or inadequate A C or D C electrical power THE LIABILITY OF KIDDE SAFETY EUROPE LTD OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS ARISING FROM THE SALE OF THIS SMOKE ALARM OR UNDER...

Reviews: