background image

6

Adding an additional wireless unit

This process is to enrol additional wireless bases to an existing

system.

1. Install and power up the new unit. The Amber and the Green

LED of the new wireless base will both be on.

2. Go to the master alarm. (See section 1 above to recognise a

master and remote RF wireless base). 

3. Press the enrol button for 1-2 seconds on the master RF wireless

base. The amber LED will flash on for 2 seconds and off for 2

seconds. It is ready to enrol a new remote wireless base.

4. Press the enrol button for 1-2 seconds on the new remote alarm

RF base. The amber LED on the wireless base will flash on for 2

seconds and off for 2 seconds. When the master unit invites it to

join the amber LED on the remote wireless base will flash 1-6

times every 4 seconds.

5. Press the enrol button on the new remote to complete the process.

The amber LED will blink rapidly indicating the remote has

completed the enrolment process.

6. Return to the master unit and press the enrol button a second time

to set the system.

Removing a wireless unit.

NOTE: Alarms can be replaced without replacing the wireless

base.

1. If a wireless base needs to be removed from the system, remove

power from the unit to be removed and wait for 5 minutes for the

master unit to recognize the error. Go to the master unit (see sec-

tion 1 as to how to distinguish between the master and remote RF

units) and verify that the amber LED is flashing (or on

continuously if there is only two units in the system). Press the

enrol button on the master RF wireless base. The amber LED will

begin to flash on for two seconds and off for two seconds.

2. Press the enrol button on the master unit a second time to finalise

the new system.

Resetting unit to factory condition.

The wireless base may be reset to the factory settings at any time by

pressing both buttons for ten(10) seconds. (this may be helpful if

there is confusion during enrollment or if the base is being relo-

cated).

1. Press and hold the function button before pressing the enrol but-

ton.

2. While holding the function button press the enrol button and hold

both until the amber LED flashes rapidly 10 times and then

remains lit.

1209-7201-02(21008418)_V2:_  2011.4.19  9:13 AM  Page 7

Summary of Contents for SLICK RF-SFTP

Page 1: ...g models with the designator 1SFW 1SFWR 2SFW 2SFWR 3SFW and 3SFWR Thank you for purchasing a Kidde Fyrnetics alarm accessory Please read through our manual in full Important information included and the manual must be left with the householder Electrical rating 230V AC 50Hz 100mA max per maximum 35mA for originating unit with 16 Devices interconnected Wireless Alarm Base 21008418 REV B 1209 7201 0...

Page 2: ...ly with this directive may lead to product failure overheating of components which is outside the terms of the guarantee WARNING This alarm cannot be operated from power derived from a square wave or modified sine wave inverter These types of inverters are sometimes used to supply power to the structure in off grid installations such as solar or wind derived power sources These power sources produ...

Page 3: ...hing never use earth conductor to interconnect use 3 core and earth cable Use black in 3 core earth cabling for interconnect line If installing using old cabling different colors take great care follow IEE Reqs A maximum of 24 Kidde devices may be interconnected in a multiple station arrangement the interconnect system should not exceed 12 Smoke Alarms and or 18 alarms total Smoke Heat CO and etc ...

Page 4: ...e with the latest I E E Regulations and complying with relevant Building Regulations Provide mains power to all units with which the rechargeable battery is turned on for service 5 Care should be taken to insure the wires are pressed firmly into the appropriate holes on the terminal block Do not use slots for wire retention see figure d Pull back lightly on each wire to verify it is seated well 6 ...

Page 5: ...Press the enrol button on this remote the amber LED will blink rapidly showing it is enrolled and that the system is still in enrolment mode 9 Repeat this procedure with all other remote alarms 10 Return to the master unit and press the enrol button This will cause the green LED to go out for one second in ten to indicate the master is broadcasting Failure to follow this procedure will cause the m...

Page 6: ... 48 hours with power contact customer support Amber LED is one for 1 sec then off for 1 sec green LED flashes ever 4 sec Unit is master unit and is in enrol mode Amber LED is flashing on and off rapidly Unit is a remote unit is enrolled but system is in enrol mode Determine if there is an obstruc tion like a large metal object that has been placed between the remote and master units causing interf...

Page 7: ...me to set the system Removing a wireless unit NOTE Alarms can be replaced without replacing the wireless base 1 If a wireless base needs to be removed from the system remove power from the unit to be removed and wait for 5 minutes for the master unit to recognize the error Go to the master unit see sec tion 1 as to how to distinguish between the master and remote RF units and verify that the amber...

Page 8: ... to clear the error On battery backup the units are not supervised and only listen for messages Re establish AC power as soon as possible Connecting the Remote Test and Hush Accessory The remote test and hush accessory model KN RTH RF is a useful portable device allowing you to test and hush the alarms within the wireless system without the requirement to physically reach the alarms test button It...

Page 9: ...ed to comply with EMC Directive 89 336 EEC R TTE Directive 99 5 EC ETSI EN 301 489 1 V1 8 1 2008 04 ETSI EN 301 489 3 V1 4 1 2002 08 ETSI EN 300 220 1 V2 3 1 2009 04 ETSI EN 300 220 2 V2 3 1 2006 04 EN 55022 2006 EN 61000 3 2 2006 EN 61000 3 3 2005 Disposal ENVIRONMENTAL PROTECTION Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check ...

Page 10: ...e following circumstances If unit has been damaged modified neglected dismantled contaminated abused or altered after the date of pur chase or if it fails to operate due to incorrect selection sitting installation maintenance or inadequate AC electrical power or damage caused by failure to abide by the instructions supplied The liability of Kidde Fyrnetics arising from the sale of this wireless ba...

Reviews: