15
8. Installation And Activation
NOTE:
The unit must be fully rotated onto the mounting bracket to activate the battery.
Activate the battery first, before installation, and push the test button to confirm
battery is activated (test sequence will follow). To allow for installation, battery will
remain active when unit is removed from mounting bracket.
NOTE:
The battery activation is a one-time feature that occurs when the alarm is
rotated fully onto the mounting bracket. Upon initial power being applied, a chirp will
be heard. After activation, the battery cannot be turned off, and can only be discharged
at the end of product life. If the alarm is removed from the mounting bracket, the bat-
tery will remain active. See Permanently Disable Alarm / Discharge Battery section.
installation instructions
CaUTiON: ThiS UNiT iS SEalEd (iNClUdiNG ThE baTTERy). ThE COVER iS
NOT REMOVablE! REMOViNG COVER Will iMPaCT dEViCE FUNCTiONaliTy aNd
VOid WaRRaNTy.
1. To insure aesthetic alignment of the alarm with the hallway or wall, the “A” line on
the mounting bracket should be parallel with the hallway when ceiling mounting or
horizontal when wall mounting.
A
A
Figure 8-A
When mounting
in a hallway, the
“A” line should
be parallel with
the hallway.
Alignment Marks
(”A” Line) on
Mounting
Bracket
Figure 8-B
When wall
mounting, the
“A” line should
be horizontal.
Figure 8-C
Remove
Install
A
A