background image

OPERATING INSTRUCTIONS

Pulse Generator
Type DG

Summary of Contents for DG 10

Page 1: ...OPERATING INSTRUCTIONS Pulse Generator Type DG ...

Page 2: ...tions CE Sign and Conformity The device meets the requirements of the valid Europe an and national regulations Conformity has been proved and the corresponding dec larations and documents are deposited with the manu facturer ...

Page 3: ...posal 6 2 1 Transport and Packing 6 2 2 Storage 6 2 3 Disposal 6 3 Design and Function 7 3 1 2 Wire Pulse Generator according to NAMUR EN 50227 7 3 2 PNP Switching 3 Wire Pulse Generator 7 4 Technical Data 8 4 1 General Technical Data 8 4 1 1 Standards and Regulations 8 4 1 2 Electrical Data 8 4 1 3 Mechanical Data 9 4 2 Dimensions 10 1 379 m 2 3 m 5 A 172 W 170 W ...

Page 4: ...g Instructions Table of Contents 5 Mounting and Dismounting 11 5 1 Scope of Supply 11 5 2 Mounting 11 5 2 1 General Mounting Instructions 11 5 2 2 Mounting and Connecting the Pulse Generator 12 6 Ordering Devices 13 ...

Page 5: ...manufacturer is not liable Make sure that the intended use is not impaired in any way even after unexpected outside influence on the de vice Intended application particularly means that any work performed with or on the device is to be carried out in accordance with these operating instructions Only skilled persons who are familiar with the Regulations on the Prevention of Accidents as well as the...

Page 6: ...the device due to transport is prevented for which the manufactur er is not liable 2 2 Storage Avoid significant variations in temperature as this can lead to condensed water which might damage the de vice The permissible storage temperature is between 25 C and 70 C Attention Keep the device clean and dry 2 3 Disposal Reuse the packing material if possible or dispose of it in an environment friend...

Page 7: ...ansis tor oscillator the high frequency stray field of which makes up the response zone When a metallic object is immersed into the effective area of the stray zone the resonant circuit is short circuited and its internal resist ance becomes high impedance The oscillations stop and the current consumption of the pulse generator de creases This current change is analysed by the rota tional speed mo...

Page 8: ...81 2 Electromagnetic Compatibility EMC Generic Emission Standard 2 Industrial Environment EN 50082 2 Electromagnetic Compatibility EMC Generic Immunity Standard 2 Industrial Environment VDE 0110 pollution degree 3 Insulation Co ordination for Equipment within Low voltage Systems 2 wire pulse generator acc to NAMUR EN 50227 DG 5 DG 10 Rated operational voltage UB DC 8 2 V DC 8 2 V Internal resistan...

Page 9: ...ent Ie 200 mA 200 mA Idle current I0 10 mA 10 mA Operating frequency 1 kHz 0 5 kHz Rated operating distance sn total tolerance zone 0 81 sn 1 21 sn dependent on the material of the actuating object 8 mm 10 mm Fitting flush flush Connecting lead 3 x 0 34 mm2 2 m long 3 x 0 34 mm2 2 m long 2 wire pulse generator acc to NAMUR EN 50227 DG 5 DG 10 Type Threaded pipe Housing diameter Tightening torque W...

Page 10: ...o resistant to oil petrol and alkaline solutions 4 2 Dimensions Degree of protection acc to EN 60529 IP 67 Temperature range Standard DG 5 TN DG 10 TN DG 5 TH DG 10 TH 25 C 70 C 40 C 70 C 25 C 100 C Fig 4 1 Mounting dimensions DG 5 DG 10 DG 5 TH TN S DG 10 TH TN S DGP 5 DGP 10 ...

Page 11: ... the head 4 of the pulse generator within the re sponse distance see fig 5 1 One pulse is generated per metal part Pulse multiplication via symmetrical ar rangement of several metal parts is recommended for low rotational speeds The metal parts should at least have the dimension of the head 4 of the pulse genera tor and the distance between any two parts should not be below the double diameter of ...

Page 12: ...uctions in section 5 2 1 and the me chanical data in section 4 1 3 3 Connect the pulse generator in accordance with the wiring diagram see fig 5 1 Fig 5 2 Mounting the pulse generator Fig 5 1 Pulse generator of the DG type series BN BU BK pnp 1 BN 2 BU NAMUR head 4 of the pulse generator fixing nuts 1 Width of the weld on plate 3 30 mm Thickness of the weld on plate 3 7 mm 40 56 26 40 6 2 6 2 16 2...

Page 13: ...tion number when you place a purchase order with Vossloh Kiepe GmbH see company address on back cover Type Device identification No DG 5 96 040 610 105 DG 5 TH 215 36 01 02 11 DG 5 TN 215 36 01 02 10 DGP 5 383 06 07 20 00 DG 10 96 040 610 110 DG 10 TH 215 36 01 02 16 DG 10 TN 215 36 01 02 15 DGP 10 383 06 07 03 00 DG 10 S 383 06 07 02 00 ...

Page 14: ...14 DG Operating Instructions 6 Ordering Devices ...

Page 15: ...15 DG Operating Instructions ...

Page 16: ...on Index Copyright reserved Subject to changes 94 056 264 191 11 10 2006 D Distribution Swizterland APS systems AG Neumatt 4 Tel 41 0 62 517 88 33 4626 Niederbuchsiten Web www kiepe elektrik ch Switzerland Mail info kiepe elektrik ch ...

Reviews: