3-8 Basic Operation
PAS SERIES
Table 3-1 CONFIG settings
■
Descriptions of setting items
CV control (DEGIT A)
Select the constant voltage control from panel control, external
voltage, external resistance, and external resistance (FAIL SAFE).
For details on external control, see "4.1 Analog Remote Control".
CC control (DEGIT B)
Select the constant current control from panel control, external
voltage, external resistance, and external resistance (FAIL SAFE).
For details on external control, see "4.1 Analog Remote Control".
Remote sensing (DEGIT C)
Set "0" to disable remote sensing, "1" to enable it.
For details on remote sensing, see "3.6 Remote Sensing".
Voltmeter
DIGIT A
DIGIT B
DIGIT C
DIGIT D
Preset
value
CV control
CC control
Remote
sensing
PWR ON
OUTPUT
0
Panel control
Panel control
OFF
OFF at startup
1
External voltage
control
External voltage
control
ON
ON at startup
2
External resistance
control
10 k
Ω
→
MAX OUT
External resistance
control
10 k
Ω
→
MAX OUT
3
External resistance
control
10 k
Ω
→
0 OUT
(FAIL SAFE)
External resistance
control
10 k
Ω
→
0 OUT
(FAIL SAFE)
Ammeter
DIGIT E
DIGIT F
DIGIT G
DIGIT H
Preset
value
Parallel/Series
master-slave
EXT OUTPUT
logic
TERMN during
digital remote
control
POWER switch trip
when the protection
circuit is activated
0
MASTER/LOCAL
HIGH=ON
OFF
Enable(shutdown)
1
Parallel slave
LOW=ON
ON
Disable(not shutdown)
2
Series slave
3
Summary of Contents for PAS 10-105
Page 10: ...VIII PAS SERIES This page has been intentionally left blank ...
Page 54: ...3 22 Basic Operation PAS SERIES This page has been intentionally left blank ...
Page 78: ...4 24 Remote Control PAS SERIES This page has been intentionally left blank ...
Page 131: ...PAS SERIES Specifications 8 13 This page has been intentionally left blank ...
Page 137: ...PAS SERIES Specifications 8 19 This page has been intentionally left blank ...
Page 145: ......