8-6 Specifications
PAS SERIES
Common Specifications
General (cont.)
Accessories
Setup guide
1 pc.
Quick reference
Japanese: 1 pc., English: 1 pc.
Safety information
1 pc.
CD-ROM
1 pc
Power cord
*1
*1.
The power cord that comes standard with the unit is for a rated voltage of 125 VAC (250
VAC for the 1 000W type).
The power supply unit operates using a nominal supply voltage in the range of 100 VAC
to 240 VAC without switching. However, if the 350W or 700W type is used under a sup-
ply voltage outside the 100 VAC to 120 VAC range, an appropriate rated power cord
must be prepared.
The power cord included in the package may vary from the specifications due to the
shipment destination.
350W and
700W types
SVT3 18AWG 3 P plug,
with connector Cable length 2.5 m: 1 pc.
1 000W type
VCT3 3.5 mm2 plug,
without connector Cable length 3 m: 1 pc.
Cable clamp: 1 set
Wire color: (black, white, green/yellow or green)
Protection cover
Rear output terminal cover: 1 set
Socket for analog control connector protection: 1 pc.
(Attached to the J1 connector, with simple lock lever)
TP BUS connector
MSTB 2.5/2-ST-5.08: 1 pc.
Output terminal screw
M8 x 16: 2 sets (bolts, nuts, and spring washers)
M4 x 8: 2 sets
Sensing terminal screw
M3 x 6: 2 sets
(Attached to the sensing connector of the unit)
Electromagnetic compatibility
*2,
*3
*2.
Does not apply to specially ordered or modified PASs.
*3.
Limited to products that have the CE mark on their panels. Not be in compliance with
EMC limits unless the ferrite core is attached on the cable for connection of J1 connec-
tor.
Complies with the requirements of the following
directive and standards.
EMC Directive 2014/30/EU
EN 61326-1 (Class A
*4
)
EN 55011 (Class A
, Group 1
*5
)
EN 61000-3-2
EN 61000-3-3
Applicable under the following conditions
The maximum length of all cabling and wiring con-
nected to the PAS must be less than 3 m.
*4.
This is a Class A equipment. The PAS is intended for use in an industrial environment.
This product may cause interference if used in residential areas. Such use must be
avoided unless the user takes special measures to reduce electromagnetic emissions to
prevent interference to the reception of radio and television broadcasts.
Safety
Complies with the requirements of the following
directive and standard.
Low Voltage Directive 2014/35/EU
EN 61010-1 (Class I
*6
, Pollution degree 2
*7
)
Summary of Contents for PAS 10-105
Page 10: ...VIII PAS SERIES This page has been intentionally left blank ...
Page 54: ...3 22 Basic Operation PAS SERIES This page has been intentionally left blank ...
Page 78: ...4 24 Remote Control PAS SERIES This page has been intentionally left blank ...
Page 131: ...PAS SERIES Specifications 8 13 This page has been intentionally left blank ...
Page 137: ...PAS SERIES Specifications 8 19 This page has been intentionally left blank ...
Page 145: ......