PAS SERIES
Specifications 8-11
*6
At a measurement frequency bandwidth of 5 Hz to 1 MHz.
*7
At an ambient temperature range of 0 °C to 50 °C.
*8
The difference in the output current between the master unit and the slave unit is within
approximately 3 % of the rating.
*9
The difference in the output voltage between the master unit and the slave unit is within
approximately 3 % of the rating.
*10
Under rated load.
*11
Excludes the charge current component that flows through the capacitor of the internal
EMC filter circuit immediately after the POWER switch is turned on (within approxi-
mately 1 ms).
*12
Standard value at an input voltage of 100 VAC under rated load.
*13
At an input voltage of 100 VAC under rated load.
350W Type (cont.)
PAS
160-2
PAS
320-1
PAS
500-0.6
—
—
Output Specifications (cont.)
Current
Rated output current
2.000 A
1.000 A
600.0 mA
—
—
Maximum preset current
(typ)
*1
105 % of rating
—
—
Accuracy of setting
*2
0.5 % of 5 mA
*3
—
—
Source effect
*4
0.1 % of 5 mA
*3
—
—
0.1 % of 5 mA
*3
—
—
Ripple noise (RMS)
5 mA
—
—
Temperature coefficient
200 ppm/ °C
(during analog remote control)
—
—
Series/Parallel operation
Master-slave parallel operation
Up to 5 units including the master
unit (same models only)
—
—
Master-slave series operation
Up to 2
units
including
the master
unit
(same
models
only)
impossible
—
—
Input Specifications
Current (max)
5.0 A (100 VAC)/ 2.5 A (200 VAC)
Inrush current (max)
35 Apeak
Power (max)
500 VA
Power factor (typ)
0.980
70%
Summary of Contents for PAS 10-105
Page 10: ...VIII PAS SERIES This page has been intentionally left blank ...
Page 54: ...3 22 Basic Operation PAS SERIES This page has been intentionally left blank ...
Page 78: ...4 24 Remote Control PAS SERIES This page has been intentionally left blank ...
Page 131: ...PAS SERIES Specifications 8 13 This page has been intentionally left blank ...
Page 137: ...PAS SERIES Specifications 8 19 This page has been intentionally left blank ...
Page 145: ......