1-6
Setup
PAS SERIES
Fig.1-3 Connecting to the switchboard (
Example: PAS10-105
)
Connection procedure
1.
Check that the supply voltage is within the line voltage
range of the power supply.
Input voltage range: 100 VAC to 240 VAC
Frequency range: 50 Hz to 60 Hz
2.
Turn OFF the POWER switch.
3.
Connect the provided AC power cord to the AC INPUT ter-
minal board as shown in Fig.1-4.
4.
Attach crimp terminals to the AC power source side of the
AC power cord.
5.
Turn OFF the switchboard.
6.
Connect the AC power cord to match the L, N, and GND of
the switchboard.
Fig.1-4 Connection of the AC power cord on the unit side
PAS10-105
N
L
N
Example:
PAS10-105
Switchboard
(white of blue)
L
(black or brown)
Example circuit breaker label
For PAS10-105
exclusive use
Supplied power cord
For PAS10-105
exclusive use
(green or green/yellow)
Cable clamper
N
L
(
GND
)
AC INPUT
terminal board
N
: White or blue
L
: Black or brown
Fastening plate
Fastening plate
(
GND
)
: Green or green/yellow
Fix the covered part of the AC power
cord with the fastening plate.
Summary of Contents for PAS 10-105
Page 10: ...VIII PAS SERIES This page has been intentionally left blank ...
Page 54: ...3 22 Basic Operation PAS SERIES This page has been intentionally left blank ...
Page 78: ...4 24 Remote Control PAS SERIES This page has been intentionally left blank ...
Page 131: ...PAS SERIES Specifications 8 13 This page has been intentionally left blank ...
Page 137: ...PAS SERIES Specifications 8 19 This page has been intentionally left blank ...
Page 145: ......