PAS SERIES
Remote Control 4-21
4.2
Remote Monitoring
4.2.1 External Monitoring of the Output Voltage and
Output Current
The J1 connector consists of monitor outputs for output voltage and
output current.
Table 4-3 Monitor output of output voltage and output
current
• Shorting V MON and I MON to A COM can cause
damage to the unit.
• Monitor output rating
Output impedance: 1 k
Ω
or less
Maximum output current: Approx. 10 mA
•
The monitor outputs are used to monitor the DC voltage
(mean value). They cannot be used to accurately monitor the
AC components (ripple, transient response, etc.) of the actual
output voltage or current.
Pin No.
Signal Name
Description
1
A COM
Common for remote control input and output monitor
8
V MON
Monitor output of output voltage
0 to approx. 10 V for 0 to rated output voltage
9
I MON
Monitor output of output current
0 to approx. 10 V for 0 to rated output current
WARNING