56
PCR-M
Chapter 3 Operation
3.13 Factory Default Settings (Initialization)
If you turn the POWER switch on while holding down the RECALL key, all items
listed in Table 3-15 are set to factory default settings.
Table 3-15 Factory default settings
Item
PCR500M
PCR1000M
PCR2000M
Output
Off
Output mode
AC
Voltage range
135 V
Voltage
AC
0.0 V
DC
0.0 V
Frequency
60.0 Hz
Measured value display
RMS
Limit values
AC
Voltage upper limit
275.0 V
Voltage lower limit
0.0 V
Current limit
5.25 A
10.50 A
21.00 A
Frequency upper limit
500.0 Hz
Frequency lower limit
40.0 Hz
DC
Voltage upper limit
388.0 V
Voltage lower limit
0.0 V
Current limit
4.20 A
8.40 A
16.80 A
Current limit operation
TRIP
Locking the Panel Operation
Released
Configuration OUTPUT on phase
OFF
Phase angle
0 deg
Measured value averaging
OFF
Peak hold time
SHOr (SHORT)
Communication interface type
232 (RS232C)
RS232C baud rate
19.2 (19200 bps)
RS232C XON/XOFF control
On
GPIB address
5
Communication error trace function
OFF
Memory
A, B, and C
Voltage
AC
0.0 V
DC
0.0 V
Frequency
60.0 Hz
Voltage range
135 V
Output mode
AC
Limit values
AC
Voltage upper limit
275.0 V
Voltage lower limit
0.0 V
Current limit
5.25 A
10.50 A
21.00 A
Frequency upper limit
500.0 Hz
Frequency lower limit
40.0 Hz
Limit values
DC
Voltage upper limit
385.0 V
Voltage lower limit
0.0 V
Current limit
4.20 A
8.40 A
16.80 A
Current limit operation
TRIP