OPERation status register
(
PCR-M
)
The OPERation status register is a 16-bit register that contains conditions that are part of
the PCR normal operations.
Bit
Bit
weight
Bit name
Description
0
1
NOT USED
--
1
2
NOT USED
--
2
4
NOT USED
--
3
8
NOT USED
--
4
16
MEASuring
*1
Indicates whether measurement is in progress on the
PCR.
5
32
Waiting for TRIGger
*2
Indicates whether the PCR is waiting for a trigger
(TRIG)
6
64
NOT USED
--
7
128
NOT USED
--
8
256
CV
CV output
9
512
NOT USED
--
10
1024
NOT USED
--
11
2048
NOT USED
--
12
4096
NOT USED
--
13
8192
NOT USED
--
14
16384
NOT USED
--
15
32768
NOT USED
Always zero
*1. A summary bit of the STAT:OPER:MEAS register. Further detailed information can be obtained by
referring to this register.
*2. A summary bit of the STAT:OPER:TRIG register. Further detailed information can be obtained by
referring to this register.
Introduction
Installing the VISA library
Interface Setup
Overview of Command
Parameters
Default settings
Command (function
search)
IEEE488.2 Common Commands
Output Setting
Protection and Clearing Alarms
Triggered Control of Output
Output On/Off Phase Control
Measured Value Queries
System Configuration
Registers
Command (ABC search)
Command (Sub-system
search)
SOURce
OUTPut
MEASure and FETCh
TRIGger
SYSTem
STATus
IEEE488.2 Common Commands
Other Commands
List(PDF)
Register
Architecture
Register structure
Appendix
A List of Errors
Processing time of main
Tutorial
Programming AC Output
Programming DC Output
Triggering Output Change
Output-on Phase Control
Measurement
Waiting for Operation Complete
Panel display
Status Monitoring
Error Checking
Visual Basic 2008
AC Power Supply PCR-M series
Communication Interface Manual
PCR-M series Communication Interface Manual
KIKUSUI ELECTRONICS CORP.
151/166