Interface Setup
Interface Setup for PCR-M series
USB
(
optional
)
This interface is valid only when the optional USB interface board is installed.
A device driver supporting USB T&M Class (USBTMC) is required to control the PCR through
the USB interface. The USBTMC driver is automatically installed by the VISA library.
USB connection
Use a standard USB cable to connect the PCR to the computer.
USB configuration
1.
Press CONFIG until the interface is set to "IntF."
2.
Turn the rotary knob to set USB to "USb."
3.
Wait at least 5 seconds, and then turn the POWER switch off and on.
The settings are applied.
Service request
The PCR is equipped with service request and serial polling functions.
USB function
Complies with USB Specification 2.0
Complies with USBTMC Specification 1.0 and USBTMC-USB488 Specification 1.0
Data rate: 12 Mbps maximum (full speed)
VID
(
Vender ID
)
0x0B3E
PID
(
Product ID
)
PCR500M: 0x1009
PCR1000M: 0x100A
PCR2000M: 0x100B
PCR4000M 0x1043
Introduction
Installing the VISA library
Interface Setup
Overview of Command
Parameters
Default settings
Command (function
search)
IEEE488.2 Common Commands
Output Setting
Protection and Clearing Alarms
Triggered Control of Output
Output On/Off Phase Control
Measured Value Queries
System Configuration
Registers
Command (ABC search)
Command (Sub-system
search)
SOURce
OUTPut
MEASure and FETCh
TRIGger
SYSTem
STATus
IEEE488.2 Common Commands
Other Commands
List(PDF)
Register
Architecture
Register structure
Appendix
A List of Errors
Processing time of main
Tutorial
Programming AC Output
Programming DC Output
Triggering Output Change
Output-on Phase Control
Measurement
Waiting for Operation Complete
Panel display
Status Monitoring
Error Checking