VOLT:RANG:AUTO (PCR-M series only)
Sets AUTO function of the voltage range.
If the AUTO function is switched, the
settings are cleared,
is applied to all SEQuence groups.
Command
[SOURce:]VOLTage:RANGe:AUTO {ON|OFF|1|0}
[SOURce:]VOLTage:RANGe:AUTO?
Parameter
Value ON(1) Enable the AUTO function
OFF(0) Disable the AUTO function (default)
For the setting that is applied when *RST is sent, see this
Response
Response
Returns the voltage range setting in NR1 format in response to VOLT:RANG:AUTO?.