FREQ
Set the AC output frequency.
This is valid in AC mode and AC+DC mode (
Command
[SOURce:]FREQuency[:CC|IMMediate] {<numeric>|MINimum|MAXimum}
[SOURce:]FREQuency[:CC|IMMediate]? [{MINimum|MAXimum}]
Parameter
Value 40 to 500 (60 by default)
Unit
HZ
For the setting that is applied when *RST is sent, see this
Response
Response
Returns the AC output frequency in NR3 format in response to FREQ?.
Introduction
Installing the VISA library
Interface Setup
Overview of Command
Parameters
Default settings
Command (function
search)
IEEE488.2 Common Commands
Output Setting
Protection and Clearing Alarms
Triggered Control of Output
Output On/Off Phase Control
Measured Value Queries
System Configuration
Registers
Command (ABC search)
Command (Sub-system
search)
SOURce
OUTPut
MEASure and FETCh
TRIGger
SYSTem
STATus
IEEE488.2 Common Commands
Other Commands
List(PDF)
Register
Architecture
Register structure
Appendix
A List of Errors
Processing time of main
Tutorial
Programming AC Output
Programming DC Output
Triggering Output Change
Output-on Phase Control
Measurement
Waiting for Operation Complete
Panel display
Status Monitoring
Error Checking
Visual Basic 2008
AC Power Supply PCR-M series
Communication Interface Manual
PCR-M series Communication Interface Manual
KIKUSUI ELECTRONICS CORP.
81/166