VOLT:OFFS:TRIG
Sets the target DC voltage when
/
TRAN and a software trigger are sent.
This command is valid in DC mode and AC+DC mode (
DC|ACDC).
Command
[SOURce:]VOLTage[0]:OFFSet:TRIGgered {<numeric>|MINimum|MAXimum}
[SOURce:]VOLTage[0]:OFFSet:TRIGgered? [{MINimum|MAXimum}]
Parameter
Value
DC mode, 135V range: -194.0 to 194.0
DC mode, 270V range: -388.0 to 388.0
AC+DC mode, 135V range: This can only be set when the AC and DC
voltages are within the settable ranges defined by the voltage limits and the
AC+DC waveform peak is between -194 V and 194 V.
AC+DC mode, 270V range: This can only be set when the AC and DC
voltages are within the settable ranges defined by the voltage limits and the
AC+DC waveform peak is between -388 V and 388 V.
A SCPI error (-222, "Data out of range") occurs if outside the range.
The default value is 0.
Unit
V
For the setting that is applied when *RST is sent, see this
Response
Response
Returns the target value to which the DC voltage is to change using a trigger in NR3 format
in response toVOLT:OFFS:TRIG?.
Introduction
Installing the VISA library
Interface Setup
Overview of Command
Parameters
Default settings
Command (function
search)
IEEE488.2 Common Commands
Output Setting
Protection and Clearing Alarms
Triggered Control of Output
Output On/Off Phase Control
Measured Value Queries
System Configuration
Registers
Command (ABC search)
Command (Sub-system
search)
SOURce
OUTPut
MEASure and FETCh
TRIGger
SYSTem
STATus
IEEE488.2 Common Commands
Other Commands
List(PDF)
Register
Architecture
Register structure
Appendix
A List of Errors
Processing time of main
Tutorial
Programming AC Output
Programming DC Output
Triggering Output Change
Output-on Phase Control
Measurement
Waiting for Operation Complete
Panel display
Status Monitoring
Error Checking
Visual Basic 2008
AC Power Supply PCR-M series
Communication Interface Manual
PCR-M series Communication Interface Manual
KIKUSUI ELECTRONICS CORP.
98/166