Protection Functions and Alarms
3
Op
e
ra
ti
o
n
s
When the error code No.200's (Err.2xx) is displayed, it is an occurrence of an internal error.
Confirm the displayed error code, and contact Kikusui agent or distributor.
Releasing the alarm
Test Condition Editor
Test Executive
The alarm can be released from the BPChecker3000. Transmit the alarm release command after
eliminating the cause of alarm occurrence indicated by the error code.
If you cannot clear the alarm even when all of the causes of the alarm occurrence are eliminated,
the PFX2512 may have malfunctioned. If this happens, stop using the PFX2512 and contact your
Kikusui agent or distributor.
Warning occurrence
The PFX2512 equips the following warning features.
When there is any potential any possible activation of the
protection function, it becomes the state of "Warning" (as the
standby state) before execution of the test. The ALARM/
WARNING LED illuminates in orange. The display on the front
panel remains as the state of before occurrence of the
warning.
When the warning is occurred, the test can not be executed.
Panel display
Cause of alarms
・
Descriptions
Operating
status
Err.060
PS/B
PS_ALM
Power supply alarm
Alarm LED
illuminate
Output off
Err.061
PS_CONT
Exceeding control voltage of the power supply
Err.062
PS_OFF
No input of the power for the power supply (POWER off state)
Err.062
PS_Init
Initial charge current undetected alarm
Err.100
Cell_S_OVP
Cell software over voltage (over charge) protection
Err.101
Cell_S_UVP
Cell software low voltage (over discharge) protection
Err.102
Cell_BALANCE_V
Cell unbalance voltage detection (
Err.103
OP_Comm
Option board communication error detection
Err.104
Cell_OTP
Cell over temperature / DUT (battery) over temperature protection
See
?
Help
Example when the volage indication is
at 30 V and the warning is occurred
illuminate (Orange)
illuminate (Green)
Panel display
Description of the warning occurrence
Operating status
Availability of
settings
Remains the
present display
Idle
(SH Detect Warning)
Improper installation.
The unit is not horizontally installed or placed where
the vibration have been generated. Activates only
when the vibration sensor is set to ON status.
Illuminates the
warning LED
Disable entry of the
test conditions
Disable execution of
the test
Available
Idle
(Protection Warning)
The activation range of the DUT (battery) voltage for
the H_OVP or H_UVP.
Not available
Idle
(OHP Warning)
Overheat protection (OHP) has been activated.
The temperature of the internal circuits is
increasing.
(The cause of OHP being activated has not been
eliminated.)
Not available
See
Summary of Contents for PFX2515
Page 10: ...10 PFX2512_CE This page is intentionally blank ...
Page 58: ...58 PFX2512_CE This page is intentionally blank ...
Page 59: ...Specification This chapter contains the PFX2512 specifications and outline drawings ...
Page 86: ...86 PFX2512_CE This page is intentionally blank ...
Page 100: ...100 PFX2512_CE This page is intentionally blank ...
Page 103: ......