Different control modes can be used simultaneously.
However, simultaneous use of CV-V and CV-R or CC-V
and CC-R is not possible.
Readjustment for remote/local switching
The power supply is adjusted at the time of factory shipment
assuming a front panel operation (local control). When using
remote control (excluding output on/off using an external con-
tact), the power supply must be readjusted. Readjustment is
also necessary when switching back from remote control to
local control. For the adjustment procedure, see 6.2
.
Fig. 5-1 Control switch
J2 connector
For the connection of the J2 connector, insert the contact that
comes with the socket that is attached to the J2 connector when
you receive the power supply from the factory.
Table 5-2 lists the tools and parts (made by Omron) needed to
assemble the J2 connector socket. For details, on how to use the
tools, read the catalogue and other information provided by
Omron.
S 1
S 2
S 3
S 4
S 5
1
2
3
4
5
6
A
B
C
D
Enables CV-V or CV-R
Selects CV-V or CV-R
Selects CC-V or CC-R
Enables CC-V or CC-R
Enables master-slave
parallel operation
By factory defa
u
lt, all switches are set to the
u
p position (1)