Fig. 2-4 Confirmation of gro
u
nd (protective con-
d
u
ctor terminal)
2.7
Turning On the Power
Before turning on the POWER switch, be sure to observe the
status of OUTPUT switch. It is on when the switch is pressed
position, and it is off when the switch is depressed position.
•
If the PO
W
ER switch is t
u
rned on while the OUTPUT
switch remains on, a preset voltage or c
u
rrent is s
u
pplied
to the load.
1.
Check that the OUTPUT switch is t
u
rned off.
2.
Open the s
u
b-panel cover of the front panel to con-
firm that all levers of control switch (S1 to S5) are set
to the
u
p position (1).
3.
Check that the Remote sensing switch on the front
panel is t
u
rned off.
4.
T
u
rn on the PO
W
ER switch.
The LED on the control panel lights up.
J 1
J
2
KIKUSUI
ELECTRONICS
CORP.
WARNING
FOR CONTINUED
PROTECTION AGAINST
FIRE HAZARD,
REPLACE ONLY WITH
SAME TYPE AND
RATING FUSE.
CAUTION
TO AVOID ELECTRIC
SHOCK, THE AC POWER
CABLE PROTECTIVE
GROUNDING CONDUCTOR
MUST BE CONNECTED
TO GROUND. DO NOT
REMOVE COVERS,
REFER SERVICING TO
QUALIFIED PERSONNEL.
INPUT
AC100V 50 60Hz
MA X 2 8 0 VA
MADE IN CHINA
FUSE
AC250V
4 A ( S.B )
1
2
3
Protecti
v
e conductor terminal
CAUTION