INSTrument Command
KIKUSUI Electronics Corp.
PWR-01 Interface Manual
INSTrument Command
This product supports virtual multichannels based on the VMCB architecture.
When the product is running as a VMCB master, detected VMCB slave units can
be selected. VMCB slave units cannot be controlled directly from a PC.
INST
Specifies the channel to configure.
Insert a wait of at least 200 ms after sending the INST command.
Command
INSTrument[:SELect] <NRf>
INSTrument[:SELect]?
INSTrument[:NSELect] <NRf>
INSTrument[:NSELect]?
Parameter
Value:
0
VMCB master unit (default)
1 to 30
VMCB slave unit
(Example)
INST 7
Response
Returns the channel that is being configured in NR1 format in response to INST?.
INST:CAT
Queries the list of channels that can be configured with the INST command.
Command
INSTrument:CATalog?
Response
Returns the channels that can be configured in NR1[,NR1...] format in response to
INST:CAT?. If the multichannel function is not in use, this query returns "+0."
+0
Master unit
+1 to +30
VMCB slave unit
For example, in a system consisting of three PWR-01s assigned to channels 0, 1,
and 4, this query r0,+1,+4.