PWR-01
27
Installation and Preparation
|
Connecting to the Output Terminals
Connecting to the front-panel output terminals
The specifications of the PWR-01 apply to the rear-panel output terminals. The front-panel
output terminals may not meet the specifications.
There is no grounding terminal on the front-panel output terminals. To ground one side of the
output, connect the rear-panel chassis terminal to either the negative output terminal or the
positive output terminal.
If you are not grounding the output terminal (leaving it floating), refer to “Output Terminal
Insulation” (
) before use.
If the output current of the front-panel output terminals exceeds 10 A (typical value), the front-
panel output terminal overcurrent protection (FOCP) will be activated (
).
Necessary cables and plugs (recommended)
Polyvinyl chloride insulation cable: Nominal cross-sectional area of 0.33 mm
2
(AWG22) to
0.82 mm
2
(AWG18)
Rated voltage: 1000 V or higher
Length: Less than 3 m
Output terminal plugs: Safety plugs
Safety plugs TL41 and TL42 are available as options (
1
Attach safety plugs to the load cables.
2
Connect the load cables with safety plugs to the front-panel output ter-
minals.
To reduce the influence of noise on the output, keep the cables as short as possible.
Twist the positive and negative load cables.
WARNING
• Risk of electric shock. The front-panel output terminals are designed to be used with
safety plugs. Do not use connectors that have bare conductive parts (such as
banana plugs) to connect to the front-panel output terminals.
• Risk of heat buildup or fire.
Do not run current higher than 10 A through the front-panel output terminals.
Front-panel output terminal.
- (negative) terminal
+ (positive) terminal
Safety plugs
800W model example
Summary of Contents for PWR1201H
Page 7: ...PWR 01 7 This page is intentionally blank ...
Page 12: ...12 PWR 01 This page is intentionally blank ...
Page 74: ...74 PWR 01 This page is intentionally blank ...
Page 100: ...100 PWR 01 This page is intentionally blank ...
Page 112: ...112 PWR 01 This page is intentionally blank ...
Page 113: ...Maintenance This chapter explains how to perform cali bration ...
Page 134: ...134 PWR 01 This page is intentionally blank ...
Page 135: ...Appendix A Factory Default Settings B Options C Troubleshooting ...
Page 144: ...144 PWR 01 ...