62
PWR-01
Basic Features
|
CONFIG Settings
CF21 (
WDOG
) Communication monitoring (WATCHDOG) timer
Sets the interval for monitoring SCPI command communication (
).
The communication monitoring operates regardless of whether the product is in remote or
local (panel control) mode.
If you are not using remote control (commands), set this to “
OFF
”.
CF22 (
CC.LA
) Current setting limit
Sets whether to limit the output current setting at the OCP trip point (about 95 % of the OCP
trip point) (
p.49
).
CF23 (
CV.LA
) Voltage setting limit
Sets whether to limit the output voltage setting at the OVP trip point (about 95 % of the OVP
trip point) or at the UVL trip point (
p.48
).
CF24 (
OC.DL
) Detection time of OCP activation
Sets the time from when an overcurrent is detected to when the OCP is activated in steps of
100 ms (
).
You can also set this parameter when the PWR-01 is being used as a slave unit.
CF30 (
SC1
) CONFIG parameter shortcut registration (SC1)
Registers a CONFIG setting parameter to the front panel’s SC1 key (
).
CF31 (
SC2
) CONFIG parameter shortcut registration (SC2)
Registers a CONFIG setting parameter to the front panel’s SC2 key (
).
Display
Description
OFF
OFF
Communication monitor timer is set to off (factory default setting).
1
to
3000
1 to 3000
1 s, 3 s, 10 s, 30 s, 100 s, 300 s, 1000 s, 3000 s
Display
Description
OFF
OFF
The setting is not limited.
ON
ON
The setting is limited (factory default setting).
Display
Description
OFF
OFF
The setting is not limited.
ON
ON
The setting is limited (factory default setting).
Display
Description
0.0
0.0
0.0 s (factory default setting)
0.1
to
2.0
0.1 to 2.0
0.1 s to 2.0 s
Display
Description
00
00
CONFIG parameter not registered (factory default setting)
01
to
99
01 to 99
CF01 to CF99
Display
Description
00
00
CONFIG parameter not registered (factory default setting)
01
to
99
01 to 99
CF01 to CF99
Summary of Contents for PWR1201H
Page 7: ...PWR 01 7 This page is intentionally blank ...
Page 12: ...12 PWR 01 This page is intentionally blank ...
Page 74: ...74 PWR 01 This page is intentionally blank ...
Page 100: ...100 PWR 01 This page is intentionally blank ...
Page 112: ...112 PWR 01 This page is intentionally blank ...
Page 113: ...Maintenance This chapter explains how to perform cali bration ...
Page 134: ...134 PWR 01 This page is intentionally blank ...
Page 135: ...Appendix A Factory Default Settings B Options C Troubleshooting ...
Page 144: ...144 PWR 01 ...