PWR-01
45
Using the PWR-01 as a CV or CC Power Supply
When the PWR-01 is used as a constant-voltage power supply, the set current is the limit to
the current that can flow through the load.
When the PWR-01 is used as a constant-current power supply, the set voltage is the limit to
the voltage that can be applied to the load.
If the specified limit is reached, the PWR-01 automatically switches its operation mode. When
the PWR-01 switches its operation mode, the lighted LED, the CV LED (green) or CC LED
(red), changes to indicate the switch.
1
Press SET to change to the setting display.
The SET key lights.
2
Turn the VOLTAGE knob to set the voltage.
Voltage setting range: 0 % to 105 % of the rated output voltage
3
Turn the CURRENT knob to set the current.
Current setting range: 0 % to 105 % of the rated output current
4
Press OUTPUT to turn output on.
The SET key turns off, and the OUTPUT LED lights. When the PWR-01 is operating as
a constant-voltage power supply, the CV LED lights green. When the PWR-01 is oper-
ating as a constant-current power supply, the CC LED lights red.
Even when the output is on, you can set the voltage and current by carrying out Step2 and
Step3 while checking the actual output voltage or current.
You can set the voltage that is actually output while checking the power (
You can use the CONFIG settings to set the output-on startup state (CF02:
CV
/
CC
) (
p.58
).
Set this according to the operation mode that you are using. You can prevent overshoot from
occurring when the output is turned on by prioritizing CV when using the PWR-01 as a con-
stant-voltage power supply and by prioritizing CC when using the PWR-01 as a constant-cur-
rent power supply.
When used as a slave device, CC is automatically prioritized.
When the output is turned on, the internal capacitors are charged. Depending on the set cur-
rent, the PWR-01 may enter CC mode for an instant.
PWR401L
0 V to 42 V
PWR801L
0 V to 42 V
PWR1201L
0 V to 42 V
PWR401ML
0 V to 84 V
PWR801ML
0 V to 84 V
PWR1201ML
0 V to 84 V
PWR401MH
0 V to 252 V
PWR801MH
0 V to 252 V
PWR1201MH 0 V to 252 V
PWR401H
0 V to 682.5 V
PWR801H
0 V to 682.5 V
PWR1201H
0 V to 682.5 V
PWR401L
0 A to 42 A
PWR801L
0 A to 84 A
PWR1201L
0 A to 126 A
PWR401ML
0 A to 21 A
PWR801ML
0 A to 42 A
PWR1201ML
0 A to 63 A
PWR401MH
0 A to 5.25 A
PWR801MH
0 A to 10.5 A
PWR1201MH 0 A to 15.75 A
PWR401H
0 A to 1.943 A
PWR801H
0 A to 3.885 A
PWR1201H
0 A to 5.828 A
Summary of Contents for PWR1201H
Page 7: ...PWR 01 7 This page is intentionally blank ...
Page 12: ...12 PWR 01 This page is intentionally blank ...
Page 74: ...74 PWR 01 This page is intentionally blank ...
Page 100: ...100 PWR 01 This page is intentionally blank ...
Page 112: ...112 PWR 01 This page is intentionally blank ...
Page 113: ...Maintenance This chapter explains how to perform cali bration ...
Page 134: ...134 PWR 01 This page is intentionally blank ...
Page 135: ...Appendix A Factory Default Settings B Options C Troubleshooting ...
Page 144: ...144 PWR 01 ...