TOS9213S/ TOS9213AS
7-63
7.6.4
Messages common to all tests
IR:SCA
NW
?
(I:SCA
NW
?)
R
--
Ret
u
rns a
W
ORD-type
v
al
u
e for Hi/Lo
w
and Open/
N
ot Open.
➀
➀
IR:CO
N
TACT
CHECK (I:CCH)
W
OFF
O
N
0/1
--
Sets O
N
/OFF for the scanner contact check f
u
nction.
➁
➁
IR:CO
N
TACT
CHECK?(I:CCH?)
R
0
1
0/1
--
Ret
u
rns the O
N
/OFF stat
u
s of the scanner contact
check f
u
nction.
➀
➀
*
1.
“1020” for TOS9213S, whereas “1530” for TOS9213AS.
Header
Data
F
u
nction and response data
A
B
R/
W
Min.
Max.
Resol
u
tion Unit
N
ote 1
N
ote 2
V
DATA?
(
V
DAT?)
R
V
Monitor
v
oltage (DC
W
: 0 E3 to 99.9 E3)
(IR: 0 to 9999)
➀
➀
IDATA?
(IDAT?)
R
A
Monitor c
u
rrent (0 to 999 E-6, 1.00 E-3 to 9.99 E-3,
10.0 E-3 to 99.9 E-3, 100 E-3 to 999 E-3)
➀
➀
RDATA?
(RDAT?)
R
Ω
Monitor resistance (0.01 E6 to 9.99 E6, 10.0 E6 to
99.9 E6, 100 E6 to 999 E6, 1.00 E9 to 9.99 E9)
➀
➀
TIME?
R
s,
--
Ret
u
rns the elapsed (remaining) time (0 s to 99.9 s,
100 s to 999 s) and Rise/Test/End (0/1/3).
Ret
u
rns the elapsed time
w
hen the timer is off.
Ret
u
rns the remaining time
w
hen the timer is on.
➀
➀
MO
N
?
R
Test type (1: DC
W
; 2: IR)
Monitor
v
oltage (
W
: 0 E3 to 99.9 E3; IR: 0 to 9999)
Monitor c
u
rrent
N
orm (0 to 999 E-6, 1.00 E-3 to
9.99 E-3, 10.0 E-3 to 99.9 E-3, 100 E-3 to 999 E-3)
Monitor c
u
rrent MAX (0 to 999 E-6, 1.00 E-3 to
9.99 E-3, 10.0 E-3 to 99.9 E-3, 100 E-3 to 999 E-3)
Monitor resistance
N
orm (0.01 E6 to 9.99 E6, 10.0 E6
to 99.9 E6, 100 E6 to 999 E6, 1.00 E9 to 9.99 E9)
Monitor resistance Min (0.01 E6 to 9.99 E6, 10.0 E6
to 99.9 E6, 100 E6 to 999 E6, 1.00 E9 to 9.99 E9)
Real c
u
rrent (0 to 999 E-6, 1.00 E-3 to 9.99 E-3, 10.0
E-3 to 99.9 E-3, 100 E-3 to 999 E-3)
Imaginary c
u
rrent (0 to 999 E-6, 1.00 E-3 to 9.99 E-3,
10.0 E-3 to 99.9 E-3, 100 E-3 to 999 E-3)
Monitor c
u
rrent IR (0 to 999 E-9, 1.00 E-6 to 9.99 E-6,
100 E-6 to 999 E-6, 1.00 E-3 to 9.99 E-3, 10.0 E-3 to
99.9 E-3, 100 E-3 to 999 E-3)
Monitor resistance DC
W
(0.01 E6 to 9.99 E6, 10.0 E6
to 99.9 E6, 100 E6 to 999 E6, 1.00 E9 to 9.99 E9,
10.0 E9 to 99.9 E9, 100 E9 to 999 E9)
Elapsed (remaining) time (0 s to 99.9 s, 100 s to 999
s)
Separates Rise/Test/End (0/1/3)
u
sing “,” in this order
and then ret
u
rns it.
The res
u
lts of the pre
v
io
u
s test are ret
u
rned except
d
u
ring the test.
Ret
u
rns the monitor c
u
rrent in DC
W
, and the monitor
resistance in IR.
➀
➀
SCA
N
TYPE?
(STYP?)
R
--
Ret
u
rns the n
u
m
b
er of
v
alid channels and the scan-
ner type (Units 1 thro
u
gh 4).
(0: none; 1: TOS9220; 2: TOS9221)
➀
➀
CFAILCH?
(CFCH?)
R
--
Ret
u
rns the channel n
u
m
b
er (1 thro
u
gh 16) in the
CO
N
TACT FAIL stat
u
s.
➀
➀
Header
Data
F
u
nction and response data
A
B
R/
W
Min.
Max.
Resol
u
tion Unit
N
ote 1
N
ote 2