Shipment Examination 

 

If the packaging is externally damaged, do not accept the shipment unless the damage is listed on the Bill of 
Lading and the crate/packaging is opened in the presence of the carrier’s agent. 
If there is no visible external damage; but the contents are damaged, or goods are missing, have the carrier’s 

agent inspect the shipment immediately for concealed damage. 
On all shipments, consignee will be responsible for filing a claim with the carrier.  If replacement parts are 

required, send order to:

 

KILLION INDUSTRIES, INC. 

1380 Poinsettia Ave. 

Vista, CA  92081

 

Toll Free (800) 421-5352 ext. 120 

Fax (760) 727-1622 

parts.service@killionindustries.com 

 

Location 

 

 
 
 
 
 
 
 
 

 
 
 

Killion refrigerators are Type 1 Open Display Refrigerators and designed to operate in air-conditioned stores 
where temperature and relative humidity are maintained at or below 75°F dry bulb temperature and 55% 

relative humidity.  Avoid locations where the refrigerator is exposed to heat sources such as the sun’s rays or hot 

tables as these external heat sources can affect the refrigerator’s efficiency. 
Do not enclose refrigerated display case with walls.  There should be ample space on each side of the 

condensing unit to facilitate free airflow.  Closing off the sides by any means will cause the refrigerator undue 

strain, and could damage the compressor.   
Air drafts will affect the refrigerator’s temperature holding capability.  Be certain there is no air-conditioning or 

heating vents discharging air into the display case area.  Overhead fans, swamp coolers, or anything that 
creates a draft will disrupt the air curtain and adversely affect the refrigerator.  An open door will sometimes 

create an air movement that will sweep the refrigerated air out of the merchandising area. 
Do not locate the refrigerator under a low ceiling.  There should be at least four feet (48") of free space above 
the merchandiser at all times.  A low ceiling can lead to reduced temperature holding capacity and expose 

the unit to undue strain.  Additionally, nothing can be stacked on top of the unit, as this will also interfere with 

proper ventilation. 
Do not locate the refrigerator directly against a wall.  There should be a minimum of six inches between the 

rear of the refrigerator and any wall behind the unit. 

PRE-INSTALLATION 

Read the entire INSTALLATION SECTION before 

placing the unit in its final location. 

ATTENTION 

Lisez la SECTION d'INSTALLATION entière avant de placer l'unité 

dans son endroit final

ATTENTION 

Summary of Contents for CFFM-93-57-99

Page 1: ...Cases are shipped with generic settings Therefore a Qualified Refrigeration Service Technician should properly adjust case settings for each store s unique ambient conditions if necessary 5 Disconnect...

Page 2: ...TENTS Shipping Examination 1 Location 1 Plumbing Requirements 2 Electrical Supply 2 Refrigerated Display w High Volume Condensate Pump 3 Routine Maintenance 4 Lighting 5 Refrigeration 5 Temperature Co...

Page 3: ...sources can affect the refrigerator s efficiency Do not enclose refrigerated display case with walls There should be ample space on each side of the condensing unit to facilitate free airflow Closing...

Page 4: ...ing back into the pump reservoir Make sure that there are no sags in the length where condensate can pool and any bends in the run should be kept to a minimum Electrical Supply A licensed electrician...

Page 5: ...the drain line coming down from the ceiling 3 Locate the flex tube from the high volume condensate pump with the disconnect fitting attached Screw this into the fitting attached to the store drain lin...

Page 6: ...Vacuum interior bottom and wipe clean of sediment or deposits in coil drain pan and around condensate pump Wipe evaporator fan blades clean to remove any dirt or film that may be deposited on them Us...

Page 7: ...necessary these settings can be adjusted by a qualified Refrigeration Service Technician to accommodate a store s unique ambient conditions and for the product being displayed To reset the controller...

Page 8: ...els with slots intended for air intake or discharge DO NOT dump excess product water into the case This will cause strain on the condensate removal systems that can cause the case or condensate system...

Page 9: ...Have a qualified technician locate and reset the high pressure safety switch and restart the case 4 Is there at least four feet 48 between the top of the merchandiser and the store s ceiling Top mount...

Page 10: ...including any warranty of merchantability or fitness for a particular purpose TRANSPORTATION COSTS KILLION will pay the cost of freight for any and all parts under warranty KILLION will not accept ret...

Page 11: ...n your specific case It is typically located near the compressor 2 Hold down both the i and the x buttons for 5 seconds The parameter SPL will show on the screen 3 Tap the button The screen will show...