Refrigerated Display w/ High Volume Condensate Pump

 

1.

 

Move the refrigerated merchandiser into desired position. 

2.

 

Attach the disconnect fitting (supplied by Killion Industries) to the end of the drain line 
coming down from the ceiling. 

3.

 

Locate the flex tube from the high volume condensate pump with the disconnect 

fitting attached.  Screw this into the fitting attached to the store drain line from the 
ceiling. 

4.

 

Plug the display case into the store power supply.  Twist to lock the plug to the 

receptacle. 

5.

 

Locate the power switch at the top of the case in the compressor area and switch it to 
“ON”. 

6.

 

Let the refrigerator run for at least four hours to allow the merchandiser to cool and the 

temperature to stabilize. 

7.

 

Once the case is cool and running, it can be stocked with merchandise. 

INSTALLATION 

Summary of Contents for CFFM-93-57-99

Page 1: ...Cases are shipped with generic settings Therefore a Qualified Refrigeration Service Technician should properly adjust case settings for each store s unique ambient conditions if necessary 5 Disconnect...

Page 2: ...TENTS Shipping Examination 1 Location 1 Plumbing Requirements 2 Electrical Supply 2 Refrigerated Display w High Volume Condensate Pump 3 Routine Maintenance 4 Lighting 5 Refrigeration 5 Temperature Co...

Page 3: ...sources can affect the refrigerator s efficiency Do not enclose refrigerated display case with walls There should be ample space on each side of the condensing unit to facilitate free airflow Closing...

Page 4: ...ing back into the pump reservoir Make sure that there are no sags in the length where condensate can pool and any bends in the run should be kept to a minimum Electrical Supply A licensed electrician...

Page 5: ...the drain line coming down from the ceiling 3 Locate the flex tube from the high volume condensate pump with the disconnect fitting attached Screw this into the fitting attached to the store drain lin...

Page 6: ...Vacuum interior bottom and wipe clean of sediment or deposits in coil drain pan and around condensate pump Wipe evaporator fan blades clean to remove any dirt or film that may be deposited on them Us...

Page 7: ...necessary these settings can be adjusted by a qualified Refrigeration Service Technician to accommodate a store s unique ambient conditions and for the product being displayed To reset the controller...

Page 8: ...els with slots intended for air intake or discharge DO NOT dump excess product water into the case This will cause strain on the condensate removal systems that can cause the case or condensate system...

Page 9: ...Have a qualified technician locate and reset the high pressure safety switch and restart the case 4 Is there at least four feet 48 between the top of the merchandiser and the store s ceiling Top mount...

Page 10: ...including any warranty of merchantability or fitness for a particular purpose TRANSPORTATION COSTS KILLION will pay the cost of freight for any and all parts under warranty KILLION will not accept ret...

Page 11: ...n your specific case It is typically located near the compressor 2 Hold down both the i and the x buttons for 5 seconds The parameter SPL will show on the screen 3 Tap the button The screen will show...