Regular periodic cleaning will ensure proper operation, minimize maintenance costs, and prolong the life of 

refrigerated merchandisers.  The following maintenance should be performed every three months.  Depending 
on the conditions of your store, you may need to increase maintenance intervals. 

 

 
 
 
 

 
 
 

 

 

 

Routine Maintenance 

 

 

Clean all dust and debris from the merchandising display areas. 

 

Clean all air grills, grates, honeycombs, and panels with warm water and a mild detergent. 

 

Remove access panel(s) (lower side panel) screws to expose evaporator coil, drain pan, and 

condensate pump. 

 

Clean case interior and pull down shades with a damp rag soaked in mild soap and water.  Remove 

the shelving and display racks and clean with mild soap and water.  Wipe down light tubes and interior 

surfaces. 

 

Clean the dust from all air grills using mild soap and water. 

 

Vacuum interior bottom and wipe clean of sediment or deposits in coil drain pan and around 

condensate pump.  Wipe evaporator fan blades clean to remove any dirt or film that may be 
deposited on them.  Use caution to not bend blades with undue pressure. 

 

Clean evaporator coil with a non-acidic, EPA approved cleaner, such as Nu-Brite or Alka-Brite, or 

comparable product. 

 

Check the pumps and pump lines for blockage.  Be sure condensate pumps are operating and freely 

transferring condensate water. 

 

Replace access panels (screw into place). 

 

Vacuum the top of the case in the compressor area to remove dust and debris from the compartment. 

 

Check refrigerant level through sight glass (located near the condensing unit), if bubbles are visible, the 

unit is low on refrigerant.  (Call a qualified refrigeration service technician for service). 

ROUTINE MAINTENANCE 

Remove product to a suitable storage refrigerator while 

performing maintenance.  Turn off refrigerated merchandiser 

and disconnect from electrical source prior to performing 

maintenance. 

WARNING

Enlevez le produit sur un réfrigérateur approprié de stockage  

tout en exécutant l'entretien. Tournez le marchandiseur au  

loin frigorifié et le démontez de la source électrique avant  

d'exécuter l'entretien. 

 

AVERTISSEMENT

 

Summary of Contents for CFFM-93-57-99

Page 1: ...Cases are shipped with generic settings Therefore a Qualified Refrigeration Service Technician should properly adjust case settings for each store s unique ambient conditions if necessary 5 Disconnect...

Page 2: ...TENTS Shipping Examination 1 Location 1 Plumbing Requirements 2 Electrical Supply 2 Refrigerated Display w High Volume Condensate Pump 3 Routine Maintenance 4 Lighting 5 Refrigeration 5 Temperature Co...

Page 3: ...sources can affect the refrigerator s efficiency Do not enclose refrigerated display case with walls There should be ample space on each side of the condensing unit to facilitate free airflow Closing...

Page 4: ...ing back into the pump reservoir Make sure that there are no sags in the length where condensate can pool and any bends in the run should be kept to a minimum Electrical Supply A licensed electrician...

Page 5: ...the drain line coming down from the ceiling 3 Locate the flex tube from the high volume condensate pump with the disconnect fitting attached Screw this into the fitting attached to the store drain lin...

Page 6: ...Vacuum interior bottom and wipe clean of sediment or deposits in coil drain pan and around condensate pump Wipe evaporator fan blades clean to remove any dirt or film that may be deposited on them Us...

Page 7: ...necessary these settings can be adjusted by a qualified Refrigeration Service Technician to accommodate a store s unique ambient conditions and for the product being displayed To reset the controller...

Page 8: ...els with slots intended for air intake or discharge DO NOT dump excess product water into the case This will cause strain on the condensate removal systems that can cause the case or condensate system...

Page 9: ...Have a qualified technician locate and reset the high pressure safety switch and restart the case 4 Is there at least four feet 48 between the top of the merchandiser and the store s ceiling Top mount...

Page 10: ...including any warranty of merchantability or fitness for a particular purpose TRANSPORTATION COSTS KILLION will pay the cost of freight for any and all parts under warranty KILLION will not accept ret...

Page 11: ...n your specific case It is typically located near the compressor 2 Hold down both the i and the x buttons for 5 seconds The parameter SPL will show on the screen 3 Tap the button The screen will show...

Reviews: