Stocking / Product Load Limits 

 

The cold air re-circulating system requires free airflow through all grills, including the grill above the bottom well 
at the front of the refrigerator.   

 

 

DO NOT place product in merchandisers until case is at proper operating temperature. 

 

DO NOT stock the product so tightly that the refrigerated airflow is hampered.  Overstocking 

refrigerated merchandisers can lead to reduced temperature holding capacity and expose the unit to 

undue strain. 

 

DO NOT stock product so tightly against back wall that airflow is restricted.  There should be at least a 

one-inch gap between the back of the case and product. 

 

DO NOT block any air grills, honeycomb air discharge areas, or any panels with slots intended for air 
intake or discharge. 

 

DO NOT dump excess product water into the case.  This will cause strain on the condensate removal 

systems that can cause the case or condensate systems to leak and overflow.  The fertilizer used in floral 
display water can also plug pumps and condensate lines leading to leaks and overflow. 

 

 

 

 
 

 

 
 
 

 
 

 
 
 
 

 

Relocating / Moving 

 

Before moving or relocating a case that has been in use, it is important to remove all condensate water from 
evaporator pans, so that water damage does not occur.  A wet/dry vacuum works well to remove water.   

 

Be sure that all plumbing and electrical connections are disconnected before attempting to relocate the case.  
Follow all directions in the 

Pre-Installation

 and 

Installation

 sections when placing the unit in its new location. 

Proper product rotation is necessary to prevent 

product loss.  Move older product to the front of the 

case and set the newer product in the back. 

 

CAUTION

 

La rotation appropriée de produit est nécessaire pour empêcher 

la perte de produit. Déplacez un produit plus ancien à l'avant du 

cas et placez le produit plus dans le dos. 

ATTENTION

 

Summary of Contents for CFFM-93-57-99

Page 1: ...Cases are shipped with generic settings Therefore a Qualified Refrigeration Service Technician should properly adjust case settings for each store s unique ambient conditions if necessary 5 Disconnect...

Page 2: ...TENTS Shipping Examination 1 Location 1 Plumbing Requirements 2 Electrical Supply 2 Refrigerated Display w High Volume Condensate Pump 3 Routine Maintenance 4 Lighting 5 Refrigeration 5 Temperature Co...

Page 3: ...sources can affect the refrigerator s efficiency Do not enclose refrigerated display case with walls There should be ample space on each side of the condensing unit to facilitate free airflow Closing...

Page 4: ...ing back into the pump reservoir Make sure that there are no sags in the length where condensate can pool and any bends in the run should be kept to a minimum Electrical Supply A licensed electrician...

Page 5: ...the drain line coming down from the ceiling 3 Locate the flex tube from the high volume condensate pump with the disconnect fitting attached Screw this into the fitting attached to the store drain lin...

Page 6: ...Vacuum interior bottom and wipe clean of sediment or deposits in coil drain pan and around condensate pump Wipe evaporator fan blades clean to remove any dirt or film that may be deposited on them Us...

Page 7: ...necessary these settings can be adjusted by a qualified Refrigeration Service Technician to accommodate a store s unique ambient conditions and for the product being displayed To reset the controller...

Page 8: ...els with slots intended for air intake or discharge DO NOT dump excess product water into the case This will cause strain on the condensate removal systems that can cause the case or condensate system...

Page 9: ...Have a qualified technician locate and reset the high pressure safety switch and restart the case 4 Is there at least four feet 48 between the top of the merchandiser and the store s ceiling Top mount...

Page 10: ...including any warranty of merchantability or fitness for a particular purpose TRANSPORTATION COSTS KILLION will pay the cost of freight for any and all parts under warranty KILLION will not accept ret...

Page 11: ...n your specific case It is typically located near the compressor 2 Hold down both the i and the x buttons for 5 seconds The parameter SPL will show on the screen 3 Tap the button The screen will show...

Reviews: