Installation (continued)

10. Remove old locating pins in center rail and replace with 

new pins from package (two required). (Figure K).

Note: If opposite gear has already been replaced during this

work session, the locating pins are still good.

11. Apply small amount of Lubriplate, Vaseline or other similar

lubricant to center portion of support tube. Slide new

gear/ring assembly onto support tube and fully seat 

assembly against center rail. Make sure assembly fully

engages locating pins. (Figure L).

Note: Re-check gear to make sure it is a match for the gear 

on the opposite side of the rail.

12. Attach gear/ring assembly to center rail with new

male/female fastener. Fastener inserts into both sides of

center rail. Tighten fastener firmly, but do not over-tighten.

(Figure M).

13. Make sure all cabling and support bars are in their 

approximate correct positions. Carefully match up holes 

and recesses and re-install “heart” mechanism onto bars and

support tubes. Use rubber mallet to fully seat “heart” into

position. Re-install the two set screws in the bottom of the

“heart”. (Figure N).

Figure L

Figure N

Figure K

Figure M

Lubricate center
area of support
tube

Insert new
gear assembly

Attach Gear with
new Male/Female
Fastener

Make sure all cabling
is properly aligned

Re-install set screws

Re-install
“Heart”

Replace old locating
pins with new ones

Summary of Contents for Aspire Table

Page 1: ...center heart mechanism as outlined in steps 3 4 5 and 6 Follow steps 1 and 2 but modify to remove the top only from the side that is being replaced Table will still need to be in folded position as per step 2 but you will only be required to remove leg on one side to replace gear Continue with steps 7 through 17 as they apply to this situation Note For ease of replacement and re assembly gears sho...

Page 2: ...Figure C Save all screws that attach lock mechanism to rails Remove and save all screws and washers holding center heart mechanism and cable bars in place Figure D 4 Pull both rails loose and pivot them away from the center Figure E 5 Use an Allen Wrench to remove both set screws from the bottom of the chrome finished heart Retain the set screws Figure F Figure D Figure F Figure C Figure E Remove ...

Page 3: ...aged gear from center support tube Figure I 9 Insert new pivot ring into recess in new replacement gear If necessary tap ring lightly with rubber mallet to fully seat ring into gear Take care to not damage ring or gear Important Gears in center mechanism MUST mesh properly for correct folding action Test fit if necessary to make sure chosen replacement gear is an exact mirror match of gear on oppo...

Page 4: ...st center rail Make sure assembly fully engages locating pins Figure L Note Re check gear to make sure it is a match for the gear on the opposite side of the rail 12 Attach gear ring assembly to center rail with new male female fastener Fastener inserts into both sides of center rail Tighten fastener firmly but do not over tighten Figure M 13 Make sure all cabling and support bars are in their app...

Page 5: ...igure O 15 Re fold table frame and re attach spring and turnbuckle clevis to H bracket Use care while springs are re tensioned Figure P 16 Carefully operate table mechanism to check for proper gear mesh and bar operation with no binding or other obvious malfunction Figure Q If any gear s on opposite side of frame must be replaced repeat Steps 3 through 15 17 Unfold table frame and lock into positi...

Reviews: