background image

Trigger (ENT)

DESCRIPTION

Set technical unit
(°C/°F)

1 – Up button. It allows to increment emissivity and the 

thresholds of high and low alarm and to move to the 
next recorded value.

2 – Set button. It allows to activate or deactivate laser 

and backlight of the screen. It also allows to record 
a temperature.

3 – Mode button. It allows to navigate through the 

modes (emissivity, max. value, min. value, 
difference, average, high alarm, low alarm, TK value 
and recorded values). 

4 – Down button.  It allows to decrement emissivity and 

the thresholds of high and low alarm and to move to 
the previous recorded value.

KIRAY 200 BUTTONS

1 - Continuous measurement indicator
2 - Unit of measurement (°C / °F)
3 - Low battery indicator
4 - Low alarm indicator
5 - Temperature value :  MAX, MIN, DIF (difference between

MAX and MIN values), AVG (average), HAL (high alarm), 

LAL (low alarm),TK (K thermocouple probe temperature)
and LOG (recorded value)

6 - High alarm indicator
7 - EMS, MAX, MIN, DIF, AVG, HAL, LAL, TK and LOG indicator
8 - Temperature value
9 - Current measurement indicator
10 - HOLD indicator (fixed measurement)
11 - Emissivity value
12 - Laser in operation indicator

DISPLAY

Laser sighting output

Battery
compartment

LCD 
backlighted
display

Up button

Mode button

Down button

1

2

3

4

Backlight and 
laser button

Infrared sensor

Probe input

Set continuous
measurement (On/Off)
Set alarm (On/Off)

MODES FLOW CHART

MODE

MODE = bouton mode

SET = bouton SET

ENT = gâchette

EMS

Réglage de l’émissivité (EMS)
avec les touche haut et bas.

Affichage de la température 

maximum

Affichage de la température 
minimum

MODE

MODE

MODE

MODE

Affichage de la température 
différentielle (entre MIN et MAX)

AVG

Affichage de la température 
moyenne calculée pendant une
prise de mesure

MODE

HAL

Affichage et réglage de l’alarme

de température haute

Affichage et réglage de l’alarme
de température basse

MODE

LAL

Affichage de la température 
par la sonde thermocouple K

donnée

MODE

TK

MODE

LOG

Affichage et enregistrement des 
températures avec le bouton SET

DIF

MAX

MIN

MODE

0.95

35.2

17.3

17.9

20.3

030

015

23.5

23.5

1

Set emissivity (EMS) with up 
and down buttons

Display of maximum 
temperature

Display of minimum 
temperature

Display of the difference of 
temperature between max. 
and min. temperatures

Display of average 
temperature  calculated 
over a measurement 
period

Display and set of the 
alarm of 
high temperature

Display and set of the 
alarm of 
low temperature

Display of the 
temperature given by the 
K thermocouple probe

Display and recording of 
temperatures with SET 
button

MODE = mode button
SET = set button
ENT = trigger

info@digiparts.ch

www.digiparts.ch

DigiParts GmbH

Summary of Contents for KIRAY 200

Page 1: ...g 5 C Display resolution 0 1 C Emissivity Adjustable from 0 10 to 1 00 pre set at 0 95 Over range indication Display indication 0L for a negative over range 0L for a positive over range Laser sighting Wavelength 630 670 nm Output 1mW Class 2 II Positive or negative temperature indication Automatic no indication for a positive temperature sign for a negative temperature Display 4 digits with LCD ba...

Page 2: ...de button Down button 1 2 3 4 Backlight and laser button Infrared sensor Probe input Set continuous measurement On Off Set alarm On Off MODES FLOW CHART MODE MODE bouton mode SET bouton SET ENT gâchette EMS Réglage de l émissivité EMS avec les touche haut et bas Affichage de la température maximum Affichage de la température minimum MODE MODE MODE MODE Affichage de la température différentielle en...

Page 3: ...r To record a temperature you have to be on LOG mode then choose an empty LOG location visible and press SET button during the measurement or when the measurement is fixed HOLD From this mode you can also clear all the recorded temperatures press and keep the trigger pressed and press down button at the same time until reaching the zero recording then press SET button while keeping ENT pressed A b...

Page 4: ...y reflection on reflective surfaces the laser in the eyes Change the batteries when the indicator blinks Do not use the thermometer around explosive gas vapor or dust Do not leave the device with the lock on lock at the top right of the screen because in this configuration the instrument does not turn off automatically non Aprotéger deschamps électriquesetmagnétiqueset del électricitéstatique To p...

Reviews: