HANGZHOU KinCony ELECTRONICS CO.,LTD www.kincony.com
Pic 2-1
1
、
16 Channel Analog Input Unit: V
KC868-COL support 0-5V voltage Analog sensors.
“Read”: Read selected input channel’s data.
“Read ALL”: Read 16 Channels Analog Input channel’s data.
"Auto Read ON":Enable automatically read data according to the time interval.
"Auto Read OFF": Disable automatically read data.
Range Config:
Min and Max is the range of the
equipment.
For example: NO.2 The detection
distance of the water level sensor is 0-100M.
When the voltage is 3.3v, the water level is
100/5*3.3=66M.
2
、
16 Channel Digital Input
KC868-COLsupport DI signal, it can read the signal status and display in Red/Green color.
“Read”: Read selected DI channel’s data.
“Read ALL”: Read 16 Channels DI channel’s data.
"Auto Read ON":Enable automatically read data according to the time interval.