background image

HANGZHOU KinCony ELECTRONICS CO.,LTD                                              www.kincony.com 

 

Pic 2-1 

1

16 Channel Analog Input Unit: V 

KC868-COL support 0-5V voltage Analog sensors. 
“Read”: Read selected input channel’s data. 
“Read ALL”: Read 16 Channels Analog Input channel’s data. 
"Auto Read ON":Enable automatically read data according to the time interval. 

"Auto Read OFF": Disable automatically read data. 

Range Config: 

 

 

Min and Max is the range of the 

equipment. 

 

For example: NO.2    The detection 

distance of the water level sensor is 0-100M. 
When the voltage is 3.3v, the water level is 
100/5*3.3=66M. 
 
 
 

2

16 Channel Digital Input 

KC868-COLsupport DI signal, it can read the signal status and display in Red/Green color. 

 
“Read”: Read selected DI channel’s data. 
“Read ALL”: Read 16 Channels DI channel’s data. 
"Auto Read ON":Enable automatically read data according to the time interval. 