25
8. RS232 control
Connect the RS232 port to control
MultiSwitch 41 4K60
e. g. from a media control system using a
suitable RS232 cable.
The below command lists are used to control the switcher.
RS232 Communication protocol:
• Baud rate: 9600
• Data bit: 8
• Stop bit: 1
• Parity bit: none
Note:
• Please remember to end the commands with the termination symbols “.” or “;”
• Please type the command carefully due to case-sensitive
• Using a PC based software like Hterm or Docklight could be helpful for the initial setup and
troubleshooting
8.1 Device control
As soon as the status of the
MultiSwitch 41 4K60
changes (e. g. by pressing a button), it will send the
related feedback via RS232.
Command
Function
Command feedback
POWON.
Power on system.
POWER ON!
POWOFF.
System standby.
POWER OFF!
RST.
Restore to factory default.
FACTORY DEFAULT!
Multiswitch 41+C 4K60
VERSION V1.0.0
POWER ON!
FRONT PANEL UNLOCK!
HDMI OUT SWITCH TO AUTO MODE!
HDMI OUT SWITCH TO 1!
DIP0000!
DIP EDID0000!
SPDIF OUT ON!
IIS OUT ON!
UNLOCK.
Unlock front panel buttons.
FRONT PANEL UNLOCK!
LOCK
.
Lock front panel buttons.
FRONT PANEL LOCKED!
NAMESET [xxx]
Set the project name.
NAMESET Switcher
SET PROJECT NAME TO ‘Switcher’
NAMESETRST.
Reset the project name.
RESET PROJECT NAME TO DEFAULT!
STA.
Report system status.
RS232 QUERY STATUS!
Multiswitch 41+C 4K60
VERSION V1.0.0
POWER ON!
FRONT PANEL UNLOCK!
HDMI OUT SWITCH TO AUTO MODE!
HDMI OUT SWITCH TO 2!