Arsenic Guard
®
OWNER’S INFORMATION
11/07
Kinetico Incorporated
♦
Corporate Headquarters
♦
Newbury, Ohio 44065
♦
440-564-9111
Product No. 11997A
Maintenance
Cartridge Filter
The cartridge filter will require cleaning or replacement when you notice a drop in pressure. To clean /
change the cartridge filter:
1. Turn the system by-pass handle to the "By-pass" (yellow symbol) position.
2. Open the pressure relief valve on the top of the filter outlet.
3. Remove the filter housing by turning it clockwise with two hands, and rinse with water.
4. Remove and clean or replace the cartridge by turning it clockwise.
5. Install clean or new cartridge by turning it counterclockwise on the filter head.
6. Clean and inspect the housing seal near the top, and lubricate with silicone if needed.
7. Install the housing by turning it counterclockwise until it stops.
IMPORTANT
- Check alignment of arrows on housing to assure proper assembly.
8. Close the pressure relief valve on the top of the filter outlet.
9. Turn the system by-pass handle to the "Service" (green symbol) position.
Filtration Media Replacement
The UltrAsorb filtration media has a finite capacity for arsenic reduction and must be replaced
periodically. The frequency of media replacement is determined by influent water quality, the size of
the media beds and your total water consumption.
When to Call for Service
Water Testing
In order to assure system performance, the water quality must be tested periodically. The frequency
of testing is determined by influent water quality, the size of the media beds and your total water
consumption. Contact your authorized Kinetico dealer for the recommended water tests at the
intervals suggested.
UltrAsorb Filtration Media Replacement
When the capacity of the filtration media has been reached, the media must be replaced. Contact
your authorized Kinetico dealer for this service.
NOTE
: Some state or local codes do not allow the use of by-pass valves on systems. Consult your
Kinetico dealer for information.
2