Figure 3
ELECTRICAL CONNECTIONS
WARNING!
ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. FAILURE TO COMPLY MAY RESULT IN
SERIOUS INJURY! ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE TILE SAW DISCONNECTED FROM THE
POWER SOURCE. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!
POWER SUPPLY
WARNING:
YOUR TILE SAW MUST BE CONNECTED TO A 120V,
15-AMP. BRANCH CIRCUIT. FAILURE TO CONNECT IN THIS WAY
CAN RESULT IN INJURY FROM SHOCK OR FIRE.
120V OPERATION
As received from the factory, your tile saw is ready to run for 120V
operation. This tile saw is intended for use on a circuit that has an
outlet and a plug which looks like the one illustrated in Fig.1.
EXTENSION CORDS
The use of any extension cord will cause some loss of power. Use the
following table to determine the minimum wire size (A.W.G-American
Wire Gauge) extension cord. Use only extension cords which accept
the tool’s plug.
For circuits that are further away from the electrical circuit box, the wire
size must be increased proportionately in order to deliver ample voltage
to the motor. Refer to Fig.2 for wire length and size.
ON-OFF SWITCH AND RESET BUTTON
This tile saw comes with a toggle switch (A) Fig.3 which turns the motor
and the water pump on simultaneously (water pump plug must be
connected to the motor quick-connect plug (C) or else the water pump
will not work). To turn machine on, push the toggle switch to the “ON”
or push the toggle switch to the “OFF” to turn off the machine.
This tile saw is equipped with a circuit breaker reset button (B) Fig.3. If
the circuit is tripped and the motor stops, push the toggle switch to the
“OFF” position. Wait 10-15 minutes for the machine to cool down and
then press the circuit breaker reset button, finally push the toggle switch
to the “ON” position to turn machine on again.
If this fails, try using a dedicated circuit without any other electrical
devices plugged to it, or have a qualified electrician check your
electrical panel.
FIGURE 1
FIGURE 2
120V GROUNDED OUTLET
GROUNDING
PLUG
CURRANT
CARRYING
PRONGS
Tool’s
Amperage
Rating
3-6
6-8
8-10
10-12
12-16
Cord Size in A.W.G.
Cord Length in Feet
25
50
100 150
18
16
16
14
18
16
14
12
18
16
14
12
18
16
14
12
14
12
-
-