background image

SPECIFIC RULES FOR SAFE OPERATION

1) WARNING! RISK OF ELECTRIC SHOCK. Do not start the generator until the cord is

connected to the inlet and the generator. Any terminal may be energized when the cord

is connected. Shut down the generator prior to disconnecting the cord from this inlet and

the generator. 

2) THE OUTDOOR POWER INLET BOX IS TO BE USED AS A POWER INLET ONLY,

NOT FOR USE AS AN OUTLET. NOT FOR INDOOR USE.

3) Only use for connecting a portable generator to the source terminals of the transfer

switch, so the inlet is only energized from the generator.

4) Mount outdoor power inlet box 24” above grade (24” from the ground). 

5) USE COPPER WIRE ONLY. 

6) Use 1/2” or 3/4” conduit only. 

7)  Only  plug  one  appliance  per  receptacle.  Never  use  an  extension  cord  or  multi-plug

adaptors to get more appliances connected to the indoor outlet panel.

SPECIFIC

SAFETY INSTRUCTIONS

GETTING TO KNOW YOUR

GENERATOR HOME CONNECTION KIT

ITEMS INCLUDED IN THIS KIT

1) Outdoor power inlet box with 30 Amp. NEMA

L14-30P 4 prong plug (underneath)

2) Indoor power outlet panel with

6 NEMA 5-15R receptacles

3) 1-1/4” wide spade bit

4) 1/2” ridgid PVC conduit

5) 2 x insulating gaskets

6) Hardware for mounting 

outdoor power inlet box 

to outside of home

7) Hardware for mounting 

indoor power outlet panel 

to inside wall in home 

8) 1/2” PVC sleeve 

connector

Summary of Contents for POWER FORCE K-X7500

Page 1: ...INSTRUCTION MANUAL COPYRIGHT 2019 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC MODEL K X7500 GENERATOR HOME CONNECTION KIT...

Page 2: ...d lack of maintenance King Canada shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To take...

Page 3: ...r 4 Mount outdoor power inlet box 24 above grade 24 from the ground 5 USE COPPER WIRE ONLY 6 Use 1 2 or 3 4 conduit only 7 Only plug one appliance per receptacle Never use an extension cord or multi p...

Page 4: ...that a portable generator and a 30 Amp 125 250VAC L14 30 generator cord are not included and must be purchased INSTALLATION CONSIDERATIONS LOCATION BEFORE INSTALLATION We recommended that you check if...

Page 5: ...of the wall for any electrical wiring water pipes etc If everything looks clear continue drilling at full speed 3 Once the spade bit reaches the wall insulation reduce forward pressure to make sure t...

Page 6: ...outlet power panel assembly Pull wires out of the conduit then cut the conduit on your pencil mark Once cut reassemble the conduit to the cradle at the rear of the outlet power panel and reinsert ass...

Page 7: ...connector D Fig 9 disassemble the locking ring E as shown 5 Insert the 1 2 PVC sleeve connector A Fig 10 through the rear hole in the power inlet box secure the connector with the locking ring B remo...

Page 8: ...ten so much that it distorts the box 2 Make sure the insulation gasket s A Fig 11 is compressed enough to ensure waterproofing CONNECTING WIRES TO NEMA L14 30 PLUG 1 While holding the NEMA plug assemb...

Page 9: ...plug underneath the power inlet box installed on the outside of your home 3 Start the generator Now the LED lights of the outlet power panel inside your home should be on indicating that the panel is...