4
EN
6.
Maintenance
To ensure that the level of safety of the installation is maintained and that the system remains reliable and operational, it must be serviced regularly
in observance of the safety regulations given in this manual and established legislation.
The gearmotor must be serviced no later than 6 months after commissioning.
01.
Disconnect all power supplies
02.
Check for any deterioration in automation system components, paying special attention to erosion or oxidation of its structural parts.
Replace any parts which are below the required standard.
03.
Check that all screw fasteners are fully tightened down
04.
Check the wear of all moving parts and replace any worn components
05.
Connect the power supplies up again, and run all the tests and checks described in Chapter 5.
For the other equipment in the system, refer to its user manuals.
7.
Dispotal of the product
This product is an integral part of the automation and must be scrapped with it.
At the end of the product’s service life, the product must be scrapped by qualified staff.
This product is made up of a variety of materials, some of which can be recycled while others must be disposed of. Check that regulatory
recycling and scrapping facilities are available locally.
Caution!
– some parts of the product may contain polluting or hazardous substances which, if disposed of into the environment, constitute
serious environmental and health risks.
As indicated by the symbol, the product may not be disposed of as domestic waste.
Sort the materials for disposal, according to the methods envisaged by current legislation in your area, or return the product to
the retailer when purchasing a new version.
Caution!
– Local legislation may envisage serious fines in the event of abusive disposal of this product.
8.
Technical specifications
WARNINGS:
• All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C). • King gate
sreserves
the right to apply modifications to products at any time when deemed necessary, while maintaining the same intended use and
functionality.
MODEL
LINEAR500230
LINEAR50024
LINEAR400230
LINEAR40024
Motor voltage [V]
230
24
230
24
Frequency [Hz]
50
DC
50
DC
Max gate length [m]
4.5
4.5
3
3
Max gate weight (kg)
250
250
300
300
IP protection rating
54
54
54
54
Operating temperature [C°]
-20 to +50
-20 to +50
-20 to +50
-20 to +50
Weight of motor [kg]
6
5.5
6
5.5
Speed [m/s]
0.016
0.014
0.016
0.014
Travel [mm]
500
500
400
400
Capacitor [
m
F]
7
-
7
-
Nominal current draw [A]
1.1
1.1
1.1
1.1
Maximum current draw [A]
1.5
5
1.5
5
Nominal power draw [W]
250
30
250
30
Maximum power draw [W]
340
120
340
120
Nominal force [N]
300
300
300
300
Maximum force [N]
2000
1800
2000
1800
Cycles (cycles/hour)
24
continuous
24
continuous
Dimensions [mm]
800 x 100 x 177 h
800 x 100 x 177 h
800 x 100 x 177 h
800 x 100 x 177 h
Summary of Contents for LINEAR400230