SPECIFICATIONS &
ELECTRICAL INFORMATION
SPECIFICATIONS
Model
..............................................................................................................................................................................................KC-3124V1
Voltage
............................................................................................................................................................................................120V/240V
Horsepower
..................................................................................................................................................................................5.5 Peak HP
Amperage
..........................................................................................................................................................................................15A/7.5A
RPM (no load speed)
..............................................................................................................................................................................3,600
Phase
..............................................................................................................................................................................................................1
Hertz
..........................................................................................................................................................................................................60Hz
Operating pressure
..........................................................................................................................95-125 PSI (field adjustable to 135 PSI)
CFM @ 40 PSI
..............................................................................................................................................................................................7.6
CFM @ 90 PSI
..............................................................................................................................................................................................6.0
Tank size
............................................................................................................................................................................................24 Gallon
ELECTRICAL INFORMATION
WARNING
ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. FAILURE TO COMPLY MAY RESULT IN
SERIOUS INJURY! ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE COMPRESSOR DISCONNECTED FROM THE
POWER SOURCE. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!
GENERAL INFORMATION- 120V/240V single phase operation
This air compressor comes with a 120V/240V single phase motor prewired
for 120V operation. If 240V single phase operation is required, refer to
section 240V operation below.
WARNING:
YOUR COMPRESSOR MUST BE CONNECTED TO A 120V,
WITH A MINIMUM 15-AMP. BRANCH CIRCUIT. FAILURE TO CONNECT
IN THIS WAY CAN RESULT IN INJURY FROM SHOCK OR FIRE.
GROUNDING
Your compressor must be properly grounded. Not all outlets are properly
grounded. If you are not sure if your outlet is properly grounded, have it
checked by a qualified electrician.
WARNING:
IF NOT PROPERLY GROUNDED, THIS COMPRESSOR
CAN CAUSE ELECTRICAL SHOCK, PARTICULARLY WHEN USED IN
DAMP LOCATIONS. TO AVOID SHOCK OR FIRE, IF THE POWER CORD
IS WORN OR DAMAGED IN ANY WAY, HAVE IT REPLACED
IMMEDIATELY.
If this compressor should malfunction or breakdown, grounding provides a
path of least resistance for electric current, to reduce the risk of electric
shock. This cut-off is equipped with a cord having an equipment-grounding
conductor and grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
WARNING:
TO MAINTAIN PROPER GROUNDING, DO NOT REMOVE OR
ALTER THE GROUNDING PRONG IN ANY MANNER.
120V OPERATION
As received from the factory, your compressor is ready to run for 120V
operation. This machine is intended for use on a electrical circuit that has
an outlet and a plug which looks like the one illustrated in Fig.1.
WARNING:
DO NOT USE A TWO-PRONG ADAPTOR FOR THEY ARE
NOT IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES.
NEVER USE IN CANADA.
240V OPERATION
WARNING!
It is recommended to contact your authorized service centre or
qualified electrician to change the motor connections from 120V to 240V
and replace the power cord to a 240V model. The use of an extension cord
is generally not recommended for 220V-240V operation.
FIGURE 1
FIGURE 2
EXTENSION CORDS
The use of any extension cord will cause some loss of power. IT
IS RECOMMENDED TO USE A LONGER AIR HOSE INSTEAD
OF AN EXTENSION CORD. If you do not have a choice, use the
chart in Fig.2 to determine the minimum wire size
(A.W.G-American Wire Gauge) extension cord needed. Use only
3-wire extension cords which have 3-prong grounding type plugs
and 3-hole receptacles which accept the tool’s plug.
For circuits that are further away from the electrical circuit box, the
wire size must be increased proportionately in order to deliver
ample voltage to the compressor motor. Refer to Fig.2 for wire
length and size.
PROPERLY GROUNDED OUTLET
CURRENT CARRYING PRONGS
GROUNDING PRONG
Tool’s
Amperage
Rating
3-6
6-8
8-10
10-12
12-16
Cord Size in A.W.G.
Cord Length in Feet
25
50
100 150
18
16
16
14
18
16
14
12
18
16
14
12
18
16
14
12
14
12
-
-