background image

SPECIFICATIONS & 

ELECTRICAL INFORMATION

SPECIFICATIONS 
Model

..............................................................................................................................................................................................KC-3124V2 

Voltage

............................................................................................................................................................................................120V/240V 

Horsepower

..................................................................................................................................................................................5.5 Peak HP 

Amperage

..........................................................................................................................................................................................15A/7.5A 

RPM (no load speed)

..............................................................................................................................................................................3,450 

Phase

..............................................................................................................................................................................................................1 

Hertz

..........................................................................................................................................................................................................60Hz 

Operating pressure

..........................................................................................................................95-125 PSI (field adjustable to 150 PSI) 

CFM @ 40 PSI

..............................................................................................................................................................................................7.6 

CFM @ 90 PSI

..............................................................................................................................................................................................6.0 

Tank size

............................................................................................................................................................................................24 Gallon

ELECTRICAL INFORMATION

WARNING 

ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. FAILURE TO COMPLY MAY RESULT IN        
SERIOUS INJURY! ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE COMPRESSOR DISCONNECTED FROM THE 
POWER SOURCE. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY! 

GENERAL INFORMATION- 120V/240V single phase operation 
 

This air compressor comes with a 120V/240V single phase motor prewired 
for 120V operation. If 240V single phase operation is required, refer to   
section 240V operation below.

 

         

WARNING:

 YOUR COMPRESSOR MUST BE CONNECTED TO A 120V,  

WITH A MINIMUM 15-AMP. BRANCH CIRCUIT. FAILURE TO CONNECT 
IN THIS WAY CAN RESULT IN INJURY FROM SHOCK OR FIRE. 
 

GROUNDING 

Your compressor must be properly grounded. Not all outlets are properly 
grounded. If you are not sure if your outlet is properly grounded, have it 
checked by a qualified electrician. 
 

WARNING:

 IF NOT PROPERLY GROUNDED, THIS COMPRESSOR 

CAN CAUSE ELECTRICAL SHOCK, PARTICULARLY WHEN USED IN 
DAMP LOCATIONS. TO AVOID SHOCK OR FIRE, IF THE POWER CORD 
IS WORN OR DAMAGED IN ANY WAY, HAVE IT REPLACED              
IMMEDIATELY. 
 
If this compressor should malfunction or breakdown, grounding provides a 
path of least resistance for electric current, to reduce the risk of electric 
shock. This cut-off is equipped with a cord having an equipment-grounding 
conductor and grounding plug. The plug must be plugged into an         
appropriate outlet that is properly installed and grounded in accordance 
with all local codes and ordinances. 

 
WARNING: 

TO MAINTAIN PROPER GROUNDING, DO NOT REMOVE OR 

ALTER THE GROUNDING PRONG IN ANY MANNER. 
 

120V OPERATION 

As received from the factory, your compressor is ready to run for 120V 
operation. This machine is intended for use on a electrical circuit that has 
an outlet and a plug which looks like the one illustrated in Fig.1. 

         

WARNING:

 DO NOT USE A TWO-PRONG ADAPTOR FOR THEY ARE 

NOT IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES. 
NEVER USE IN CANADA. 

 
240V OPERATION 
WARNING!

 It is recommended to contact your authorized service centre or 

qualified electrician to change the motor connections from 120V to 240V, 
replace motor reset and replace the power cord to a 240V model. The use 
of an extension cord is generally not recommended for 220V-240V         
operation.

 

FIGURE 1

FIGURE 2

EXTENSION CORDS 

 
The use of any extension cord will cause some loss of power. IT 
IS RECOMMENDED TO USE A LONGER AIR HOSE INSTEAD 
OF AN EXTENSION CORD. If you do not have a choice, use the 
chart in Fig.2 to determine the minimum wire size   
(A.W.G-American Wire Gauge) extension cord needed. Use only 
3-wire extension cords which have 3-prong grounding type plugs 
and 3-hole receptacles which accept the tool’s plug. 
 
For circuits that are further away from the electrical circuit box, the 
wire size must be increased proportionately in order to deliver 
ample voltage to the compressor motor. Refer to Fig.2 for wire 
length and size.

PROPERLY GROUNDED OUTLET

CURRENT CARRYING PRONGS

GROUNDING PRONG

Tool’s 

Amperage 

Rating 

 

3-6 
6-8 

8-10 

10-12 
12-16

Cord Size in A.W.G.

Cord Length in Feet 

   25     50    100   150

   

18

    

16

    

16

     

14 

   

18

    

16

    

14

     

12 

   

18

    

16

    

14

     

12 

   

18

    

16

    

14

     

12 

   

14

    

12

      

-

       

-

Summary of Contents for KC-3124V2

Page 1: ...INSTRUCTION MANUAL MODEL KC 3124V2 COPYRIGHT 2018 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC 5 5 PEAK HP 24 GALLON AIR COMPRESSOR...

Page 2: ...ty does not apply to defects due directly or indirectly to misuse abuse normal wear and tear negligence or accidents repairs done by an unauthorized service center alterations and lack of maintenance...

Page 3: ...system RISK OF BURNS WHAT CAN HAPPEN Touching exposed metal such as the compressor head or outlet tubes can result in serious burns HOW TO PREVENT IT Never touch any exposed metal parts on compressor...

Page 4: ...g conductor and grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING TO MAINTAIN PROPER...

Page 5: ...ELY FOLLOWED THESE PROCEDURES ARE REQUIRED BEFORE THE AIR COMPRESSOR CAN BE PUT INTO SERVICE AFTER REPLACING THE CHECK VALVE AND WHEN A PISTON OR A CYLINDER SLEEVE ARE REPLACED 1 Make sure the pressur...

Page 6: ...explosion Daily pull the ring on the safety valve to make sure that the safety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the same ASME type of...

Page 7: ...il level must be in the centre of the red dot of oil sight glass 2 Drain condensation from tank 3 Check for any unusual noise or vibration 4 Be sure all nuts and bolts are tight Monthly 1 Inspect air...

Page 8: ...Crankcase breather valve malfunction Worn piston rings Piston rings not seated CORRECTIVE ACTION Check voltage or eliminate extension cord or reset Check wiring connections Wait for motor to cool then...

Reviews: