11) Use extra care when collecting dust on stairs.

12) To avoid injury from accidental starting, unplug power cord before

changing or cleaning the drum plastic bag or the canister filter

plastic bag.

13) Do not use without the canister filter plastic bag in place.

14) Do not unplug by pulling on the cord. To unplug, grasp the plug,

not the cord.

15) Turn off controls before turning off.

16)  Do  not  use  with  damaged  cord,  plug  or  other  parts.  If  your

cyclone  dust  collector  is  not  working  as  it  should,  has  missing

parts, has been dropped, damaged, left outdoors, or dropped into

water, send for servicing.

17) Do not pull or carry by the cord, use cord as handle, close a door

on cord, or pull cord around sharp edges or corners. Do not run

your cyclone dust collector over the cord. Keep cord away from

heated surfaces.

18) Do not handle the electrical plug with wet hands.

19) Do not put any objects into the ventilation openings. Do not vacuum

with any ventilation opening blocked, keep free of dust, lint, hair or

anything that may reduce the air flow.

20) Keep hair, loose clothing, fingers and all other parts of the body

away from openings and moving parts.

21) Extension cords in poor condition or that are too small can pose

fire  and  shock  hazards.  When  using  an  extension  cord,  make

sure it is in good condition. 

22) Connect to properly grounded outlet only.

23) USE the cyclone dust collector to pick up wood materials only.

DO NOT use to pick up metal shavings, dust, water, or parts.

24) DO NOT handle the plug or cyclone dust collector with wet hands. 

cAutIon:

If using this cyclone dust collector to keep airborne wood

dust  in  heavy  usage  within  acceptable  limits,  you  must  regularly

monitor airborne dust and maintain the cyclone dust collector to avoid

exceeding dust limits. Each application is unique. Your maintenance

schedule must therefore be tailored to your specific use.

Safety is a combination of common sense, staying alert and knowing

how your dust collector works.

wArnInG:  to  AVoId  MIstAkes  tHAt  could  result  In

serIous,  PerMAnent  InJury,  do  not  connect  tHe

Power  cord  untIl  tHe  FollowInG  stePs  HAVe  been

coMPleted:

1) Assembly, mounting and alignment.

2) Learn the function and proper use of the ‘’ON/OFF’’ switch.

3)  Read  and  understand  all  instructions  and  operating  procedures

throughout the manual.

beFore eAcH use:

1) Inspect your cyclone dust collector. If any parts are missing, bent,

or  fail  in  any  way,  or  any  electrical components  do  not  work

properly, turn off the cyclone dust collector and remove the power

cord from the power supply. Replace damaged, missing or failed

parts before using the cyclone dust collector again.

2) Plan your work to protect your eyes, hands, face, ears and body.

3) 

weAr sAFety GoGGles.  ‘’ForesIGHt Is better tHAn

no sIGHt’’

. Wear safety goggles, not glasses, that comply with

ANSI Z87.1. Operating any power tool can result in foreign objects

being  thrown  into  the  eyes  which  can  result  in  permanent  eye

damage.

4) When cleaning the dust collector plastic bags, wear a dust mask.

cAutIon:

The blower housing contains a high speed fan blade that

can  amputate  fingers,  grab  loose  clothing  and  neckties,  or  propel

dust at high velocities. 

do not oPerAte wItHout All PArts

In PlAce

.

Do not attempt to clean, remove plastic dust bags or service while in

operation. Disconnect from power source.

sPecIFIc sAFety InstructIons 

For your cyclone dust collector

Summary of Contents for KC-6300C

Page 1: ...InstructIon MAnuAl MODEL KC 6300C COPYRIGHT 2018 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC 3 HP cyclone dust collector...

Page 2: ...o defects due directly or indirectly to misuse abuse normal wear and tear negligence or accidents repairs done by an unauthorized service center alterations and lack of maintenance King Canada shall i...

Page 3: ...ies or attachments 16 AVoId AccIdentAl stArtInG Make sure the swich is in the OFF position before plugging in 17 use recoMMended AccessorIes Consult the manual for recommended accessories Follow the i...

Page 4: ...r to keep airborne wood dust in heavy usage within acceptable limits you must regularly monitor airborne dust and maintain the cyclone dust collector to avoid exceeding dust limits Each application is...

Page 5: ...OR ALTER THE GROUNDING PRONG IN ANY MANNER wArnInG IF NOT PROPERLY GROUNDED THIS CYCLONE DUST COLLECTOR CAN CAUSE ELECTRICAL SHOCK PARTICULARLY WHEN USED IN DAMP LOCATIONS TO AVOID SHOCK OR FIRE IF T...

Page 6: ...filter 10 Canister filter handle for cleaning 11 Remote control 12 On button 13 Off button 14 Increase timer setting 15 Decrease timer setting 16 Timer setting indicator lights Motor MODEL KC 6300C H...

Page 7: ...ssembly should be performed by two people Lift up the main impellor housing A Fig 6 and position it over the left and right stands B 4 Secure the main impellor housing A to the stands B using flange h...

Page 8: ...r filter A and the outlet of the main impellor housing C using the small hose clamps K 10 Stick foam A Fig 8 around the lip on the cone B and around the lip of the drum lid C Then install and secure t...

Page 9: ...heat Every effort should be made to prevent foreign material from entering the motor A visual inspection should be made at frequent intervals Accumulations of dry dust can usually be blown out to prev...