34
No.
Name
Icon
Sleeping
working
state
Wakening working state
Activity working state
1
A/C on/off key in
driver zone
-
Display “OFF” through screen
by key (pressing more than 2
Sec.) to turn on heating in
driver zone, without cooling
function; once more pressing
key more than 2 Sec., thus the
A/C is closed in driver zone.
Once switch key lies in “ON” state while turning off last time,
in that way, switch key will lie in “ON” state when entering
into activity mode; Once switch key lies in “OFF” state while
turning off last time, thus, switch key will lie in “OFF” state
when entering into activity mode, may turn on by pressing
key(less than 2 Sec.), and A/C in driver zone run automatically
according to the remembered temperature parameter when
turn off last time. The A/C in driver zone will turn off if
pressing key (more than 2 Sec.). When the key ”AUTO” mode
is pressed down( less than 2Sec.), will close defrosting and
dehumidification mode if they are operating.
2
TEMP adjust rotary
knob in driver zone
-
-
Increase setting temperature at rotating clockwise and
decrease setting temperature at rotating anti-clockwise. If the
A/C in passenger zone run and set temperature “TP”, thus the
setting temperature in driver zone will be temperature “TC”
and only set “TC±3”centigrade in scope of 17-27 centigrade.
Once the A/C in passenger zone is turn off, TC could select
freely one value in scope of 17-27 centigrade; if temperature is
less than 17centigrade, then set “LO” corresponding to
maximum cooling power; if temperature is more than
27centigrade, then set “HI” corresponding to maximum
heating power; the set temperature value in driver zone
indicate the display screen.
3
WIND decreasing
key in driver zone
-
Blower’s speed only set one
gears, not adjustable, the
speed value in driver zone
may be indicated on display
screen.
When pressing down left key, decrease ventilation fan speed;
when pressing down right key, thus increase ventilation fan
speed, ventilation fan’s speed could be set in scope of 1-5
gears, automatic mode in driver zone will void by changing
gears.
The minimum blower speed selected by manual style is 2th
gears to prevent evaporator from defrosting while compressor
run and feed-liquid solenoid valve opened. If the blower speed
is less than 2th gears, the blower speed will automatically
upgrade to 2th gears once compressor and feed-liquid solenoid
valve opened.
The blower speed will not be changed by manual style while
in defrosting/dehumidification mode, in the mode of
defrosting, the blower speed will be set in 5th gears-the
highest gears.
The Blower speed value in driver zone indicates in display
screen.
4
WIND increasing
key in driver zone