Common trouble and elimination
C-20
Electric system trouble and remedy
Fault
symptom
Possible cause
Eliminating method
the power
lamp on the
control
panel not
light
1.
+ no power supply
;
2.
D+ not connected well
;
3.
harness not tight
;
4.
control unit failure
;
1.
generator D+ no output, exchange
the generator and repair
2.
reconnect the cable D+
;
3.
reconnect the harness
;
4.
change the control panel or repair
;
malfunction
light on the
control
panel light
up
1.
system pressure error
;
2.
pressure switch defective
;
3.
pressure switch harness not
connected well
;
4.
harness connection not well
;
5.
control panel failure
;
1.
to connect the manifold gauge and
eliminate the malfunction
;
2.
change the pressure switch and
repair
;
3.
reconnect the pressure switch
;
4.
harness connection;
5.
change the control panel or repair
;
refrigerant
lamp is not
lighted up
1.
defrost sensor failure or
connection problem
;
2.
temperature control sensor
failure or connection problem
;
3.
temperature control sensor
installation position not
good
;
4.
temperature control switch
defective
;
5.
harness connection not
reliable
;
6.
Control panel defective
1.
change the defrost sensor or
connect the cable again
;
2.
change the temperature control or
connect the harness again
;
3.
re-install the temperature control
into the correct position
;
4.
change the temperature control
switch or repair
;
5.
harness connection again
;
6.
change the control panel or repair
;
condenser
fan not
working
1.
malfunction lamp light up
;
2.
sensor failure
;
3.
relay failure
;
4.
fuse burnt
;
5.
battery not charge or
connection loose
;
6.
harness connection not tight
;
7.
air blower connection loose
;
8.
air blower failure;
9.
control panel failure
;
1.
check the problem according to the
item 2
;
2.
change sensor or sensor connection
cable
;
3.
change the relay or repair the relay
of the connecting harness
;
4.
change the fuse
;
5.
change the battery or recharge the
battery ,make the connection
;
6.
re-connect the harness
;
7.
connecting to the venting cable
;
8.
change the blower or repair
;
9.
change the control panel or repair
;
Summary of Contents for XMQ6129Y series
Page 47: ...Technical parameter and complete vehicle description 0 T 1 TPMS OPERATION...
Page 48: ...Technical parameter and complete vehicle description 0 T 1...
Page 49: ...Technical parameter and complete vehicle description 0 T 1...
Page 50: ...Technical parameter and complete vehicle description 0 T 1...
Page 51: ...Technical parameter and complete vehicle description 0 T 1...
Page 52: ...Technical parameter and complete vehicle description 0 T 1...
Page 53: ...Technical parameter and complete vehicle description 0 T 1...
Page 54: ...Technical parameter and complete vehicle description 0 T 1...
Page 55: ...Technical parameter and complete vehicle description 0 T 1...
Page 56: ...Technical parameter and complete vehicle description 0 T 1...
Page 57: ...Technical parameter and complete vehicle description 0 T 1...
Page 63: ...Technical parameter and complete vehicle description 0 K 1 Lock1 Lock 2 Lock 3...
Page 157: ...Appendix A 4 Air braking schematic diagram...
Page 158: ...Appendix A 4 Electric schematic diagram of the complete vehicle 1...
Page 159: ...Appendix A 5 Electric schematic diagram of the complete vehicle 2...
Page 160: ...Appendix A 5 Electric schematic diagram of the complete vehicle 3...
Page 161: ...Appendix A 5 Electric schematic diagram of the complete vehicle 4...