Serial Device Server D224

RS232/485/TTL To TCP/IP

Basic Settings

Basic Function

Button

Description

Default

Restore to factory settings(need click save after default

Change PWD

Modify device password

Read

Read all current configuration parameters of the device

Save

Save all configuration parameters to the device

Restart

Restart the device after saving

The step of modifying configuration parameter:
1) Modify configuration parameter;
2) Click

Save

until prompt

save success

,then click

Confirm

Summary of Contents for D224

Page 1: ...User Manual Ver 1 0 D224 Date Issued 2019 07 08 All rights reserved by King Pigeon Hi Tech Co Ltd www IOT Solution com Serial Device Server D224 RS232 485 TTL To TCP IP ...

Page 2: ...ARE VERSION DESCRIPTION 2019 07 08 V1 0 V1 0 First edition This handbook has been designed as a guide to the installation and operation of Serial Server D224 Statements contained in the handbook are general guidelines only and in no way are designed to supersede the instructions contained with other products We recommend that the advice of a registered electrician be sought before any Installation...

Page 3: ...anagement and data accessibility to thousand of devices that can not connect to a network It is the most popular industrial internet of things IIOT gateway The serial device server suitable for below applications Serial Devices to TCP IP Communication and IoT Cloud Platform Serial Devices to Serial Devices communications e g PLC to PLC Equipment networking in the field of access control security V...

Page 4: ... 232 1 channel RS 485 and 1 channel TTL Serial port baud rate supports 4800bps 128000 bps supports None Odd Even check mode Supports 1 channel RJ45 Ethernet port with link and data indicator built in isolation transformer up to 2KV electromagnetic isolation Support RESET button to recovery the parameters to factory defaults long press for 3 seconds to recover prevent parameter setting error Metal ...

Page 5: ...er after disconnection Support serial port strategy function data path is free to choose for example RS232 and RS485 bi direction communication RS232 RS485 RS232 and server 1 bi direction communication RS232 server 1 Can be used as a repeater for two serial device communications directly e g PLC to PLC Support firmware upgrade through TTL firmware update is more convenient Small in size 96mm 68mm ...

Page 6: ...ansmitting data by Ethernet port the LED will be on otherwise it is off Interface Instructions for installation RESET Reset button Recovery the parameters to factory default value RS232 RS232 port ETH RJ45 Ethernet port RS485 A RS485 data A B RS485 data B GND RS485 data ground if required TTL TXD Transmit data port RXD Receive data port GND Data ground if required 9 36 VDC DC9 36V negative input D...

Page 7: ...he parameters by PC Configuration please follow it step by step Start to Configure Step1 Connect The Configurator in the CD or download from www iot solution com then installs it on the computer Step2 Connect External DC Power Connect the external DC Power 9 36V to DC in 9 36V Ports Step3 Run the Configuration software Compatible with Windows XP Vista 7 8 10 Tips In some computer it required downl...

Page 8: ... Device Button Instruction Default IP Device IP address in the LAN Model Device model Name Device name can customize after connecting successfully MY_D224 Version Device firmware version Dual click device list will appear below Enter password default 1234 click Confirm prompts success then will read device configuration parameter automatically ...

Page 9: ...efault Restore to factory settings need click save after default Change PWD Modify device password Read Read all current configuration parameters of the device Save Save all configuration parameters to the device Restart Restart the device after saving The step of modifying configuration parameter 1 Modify configuration parameter 2 Click Save until prompt save success then click Confirm ...

Page 10: ...ly Ethernet Settings Network Setting Button Description Default IP Model The mode to get IP Dynamic address get IP automatically from DHCP server Static address Manually configure a static IP Dynamic address IP Address Set IP address Port The port when act as a TCP UDP server range 0 65536 502 Subnet Mask The device subnet mask Gateway The device gateway address DNS Server The device DNS server ad...

Page 11: ...el Select and view the currently used serial channel includes TTL RS232 RS485 RS485 Baud Rate 4800 9600 14400 5600 57600 19200 38400 115200 128000 optional 115200 Data Bits 5Bit 6Bit 7Bit 8 Bit optional 8 Bit Parity Bits NONE EVEN ODD optional NONE Stop Bits 1Bit 1 5 Bit 2Bit optional 1Bit Click Serial Strategy as below it is for configuring data transmission path default supports 3 paths ...

Page 12: ...t target servers at the same time every server supports rich automatic handshake login message self defined heartbeat message data transparent transmission and Modbus RTU to Modbus TCP device can be quickly compatible with multiple third party cloud platform systems Server Settings Button Description Default Server 1 5 Supports 5 different target servers at the same time Server 1 IP Domain Target ...

Page 13: ...urned by the target server after receiving the heartbeat data Empty Heartbeat Interval The interval time of sending heartbeat data range 1 999 second 10 Client Settings Supports up to 5 TCP UDP Clients and 5 TCP UDP Servers connections simultaneously Client Settings Button Description Default TCP UDP Model TCP UPD TCP UPD optional TCP Transfer Protocol Transparent Modbus RTU Modbus TCP optional Tr...

Page 14: ...lly 8 Application 8 1 Extend the serial device communication distance Connect 2 serial devices with 2 D224 can realize data communication 2 D224 must be connected by crossover cable One D224 works as TCP Server another D224 works as TCP Client D224 as server the IP needs to be set to static and the IP address should be in the same network segment with another D224 as below Reset button ...

Page 15: ...of 19 King Pigeon Hi Tech Co Ltd www iot solution com Ver 1 0 File No D224 V1 0 Serial Device Server D224 RS232 485 TTL To TCP IP Serial strategy add a path RS232 Client Client parameter settings are as follows ...

Page 16: ...32 485 TTL To TCP IP Serial strategy add a path RS232 Server 1 Default added 8 2 Multi device connect to cloud platform D224 supports RS232 RS485 and TTL type devices to connect the cloud platform at the same time The following figure shows the D224 connecting two serial devices to the cloud platform at the same time ...

Page 17: ...the corresponding information for the IP domain name and port Default KingPigeon KPIIOT cloud platform Setting as follows 8 3 Connect multiple servers Simultaneously As a TCP client D224 can connect 5 servers at the same time If the serial device RTU device used as master and server 1 5 Modbus TCP device as the slave at the same time there are multiple network port slave devices up to 5 then the s...

Page 18: ... TCP IP 8 4 Local configuration and connect to the cloud platform The D224 used as server and supports client functions For RS232 devices Modbus slaves local configuration can be implemented allowing the computer in the LAN Modbus master to initiate commands and simultaneously receive commands from the cloud platform Modbus master ...

Page 19: ...resent functions caused it should update the firmware the user can upgrade them directly by USB port If you required upgrade please contact us to modify the firmware according to you requirements and we will provide the upgraded firmware to you to upgrade them 10 Warranty 1 This system is warranted to be free of defects in material and workmanship for one year 2 This warranty does not extend to an...

Reviews: