6.4 Digital Input.
The RTU5025 equips 2 digital inputs.
DIN1 special for secure door and automatically armed when door closed, SMS alert send to the 1
st
~6
th
positon
number immediately when door opened illegally.
DIN2 for motion/smoke or other sensors to protect your assets, SMS alert send to the 1
st
~6
th
positon number
when there have any alarm occurance.
On alarming situation,after alert SMS send out,RTU5025 will call the 1
st
number and next number if there have no
answering.
6.4.1 Arm: Disarm:
6.4.2 Define the DIN1/ DIN2 type.
Eg:
1234DIN2NO#
,
define the DIN2 as NO(Normally Open) type.
6.4.3 Modify the Alert SMS content when inputs alarm(Max. 32
characters).
E.g.:
1234M2#Window open alarm!#
Modify the DIN2 alert SMS
content to “Window open alarm!”
DIN1 default alert SMS content: Door opened illegally.
DIN2 default alert SMS content: DIN2 Alarm.
6.4.4 Inquiry the NC/NO type and Alert SMS content of DIN1(2).
6.4.5 Digital alarm conditions.
The DIN1/DIN2 will trigger an alarm only under the below two coditions
RTU5025 under the Armed Mode
10mins after the last call in from the authorized numbers. (10mins default,users can modify the time period by
SMS command:
xxx=000~999, unit:minute
xxx=000: RTU5025 will always disarm untill arm by SMS command.
pwdAA
!
pwdBB
!
pwdDIN
1
NC(NO)#
!
pwdM1(2)#sms conenton#
#
pwdMQ#
!
pwdDxxx#
!
pwdDIN
2
NC(NO)#
!