CAUTION: Low
Water Flow
Power On/Off
OUTPUT LEVEL
7
6
5
4
3
2
1
CAUTION:
Salt Level High
Set dial to achieve
desired output level.
IMPORTANT: Fine
tuning is possible
without indicator
lights changing.
See side panel or
manual for
additional
directions.
9
Controls
1. OUTPUT LEVEL
—
The lights marked 1-7 indicate the system’s chlorine output.
The higher number indicates higher chlorine production. Turning the control knob
clockwise increases chlorine production and should increase the chlorine output
reading. To turn system off, turn knob all the way counterclockwise until power
light turns off.
2. SALT LEVEL
—
The lights marked 1-7 also indicate adequate or inadequate
salt levels.
To check the salt level
, turn the control knob all the way up (clockwise) and
check the light reading.
A) If light number 7 is lit,
the salt level is sufficient. (Return the control
knob to the desired chlorine production setting.)
B) If any number less than 7 is lit,
the salt level could be low or the cell is
worn or calcified. Check the cell to ensure the plates are in good condition
and not coated with calcium buildup (a white chalky coating on the plates
inside the cell). Cleaning the cell is recommended if it is calcified or if the
readout seems questionable (see page 11). Before adding salt, it is
advisable to have the salt level professionally checked by your dealer.
C) If lights 1-7 go up and down quickly or the salt-level high light is solid,
the salt level is extremely high and should be reduced immediately by
draining a significant amount of pool water and refilling the pool. (Please
check with your local pool professional prior to draining the pool.)
3. IF THE CAUTION: SALT-LEVEL HIGH LIGHT IS FLASHING
—The salt level
in the pool is on the high side. This does not harm the POOL FROG
®
Mineral
Hybrid Generator, but is provided as a cautionary notice to the user not to add
more salt to the pool. Operation at very high levels (i.e. above 5500 ppm) is not
recommended. Return the control knob to the desired chlorine production setting.
If this light is solid red, see 2C above.
4. POWER LIGHT
—When the system is turned on and the pump is operating,
the green power light should be illuminated indicating that power is reaching the
control panel.
5. CAUTION: LOW-WATER FLOW LIGHT
—
Red light should NOT be illuminated
during normal operation. When first turning on the circulation pump, the red light
may turn on and off until the air is pushed out of the pump lines and sufficient
water flow is achieved. This is normal and ensures that the generator automatically
shuts off if the pump fails to prime or a blockage occurs. See troubleshooting
section if red light remains on.